User Manual

Section 6 APPENDIX
Section 6
Error Messages and Corrective Actions
119
ZFV-C
User’s Manual
Error Messages and Corrective Actions
In the following instances, error messages are not displayed, but the ERROR and ERR
lmap turn ON.
Error Message Cause Countermeasure Page
HEAD IS NOT CON-
NECTED
The Sensor Head is not connected
correctly.
Make sure that the Sensor Head is
connected correctly.
p.51
NEIGHBOR UNIT IS
NOT CONNECT
The Amplifier Units are not coupled
correctly.
Make sure that the Amplifier Units are
connected correctly.
p.36
SYSTEM ERROR Failed to configure FPGA.
Failed to initialize LCD.
Failed to recognize Amplifier Unit.
Failed to load data from flash memory.
Faulty hardware operation
Faulty software operation
Faulty Amplifier Unit Contact your
OMRON representative.
-
TEACHING FAILED The workpiece is not projected cor-
rectly.
The teaching area is not set at the
appropriate position.
Set the area so that the workpiece is
projected in the field-of-view.
Make sure that the appropriate teach-
ing area is set.
p.47
COLOR EXTRAC-
TION FAILED
Teaching cannot be performed since
no color pickup setting has been
made.
Make color pickup setting (color), then
perform teaching again.
p.61
p.152
p.158
DIFFERENT PASS
NUMBER
The lock function cannot be cancelled
because of an incorrect pass number.
Input the registered pass number. p.105
SYSTDATA ERROR Data saved to the instrument has
been damaged.
The currently set system data is
cleared. Set the system data again.
p.96
BANKDATA ERROR The current bank data has been dam-
aged.
The currently set bank data is cleared.
Set the bank data again.
p.94
HEAD ERROR Failed to communicate with the sensor
head.
Make sure that the sensor head is
connected correctly.
High-voltage lines and power lines
must be wired separately from this
product.
-
Cause Countermeasure Page
TRIG was input while ENABLE was OFF. Wait until ENABLE is turned ON and then input TRIG. p.42
Failed to teach from external device. Set the area so that the workpiece is projected in the field-
of-view.
Make sure that the appropriate teaching area is set.
Make sure that TRIG timing is appropriate in the workpiece
move teaching mode.
p.47
p.42