Setting for Amplifier Unit Gang-Mount
Rules of Gang-Mounting
Item Rules
No. of Amplifier Units connectable 5 or less (power must be supplied to each Amplifier Unit)
No. of mounted sensor heads Up to the number of amplifier units
TRIG signal input Only host device is enabled
TEACH signal input Only host device is enabled
BANK1-3 input Enabled at each amplifier unit
ENABLE output Only host device is enabled
OUTPUT output Depends on the settings (Integrated judgment/Individual judgment)
ERROR output Enabled at each amplifier unit
MENU/ADJ/RUN Only host device is enabled
STD/EXP Enabled at each amplifier unit
All key inputs Enabled at each amplifier unit
TRIG signalENABLE signal
Amplifier unit for inputting furthest
right TRIG signal = host device
Amplifier unit without TRIG signal inputs = client device