User Manual
108
Section 5 SETTING ADDITIONAL FUNCTIONS
ZFV-C
User’s Manual
Section 5
Changing OUTPUT Signal Output Conditions
■ Selecting One-Shot output ON/OFF
Set whether or not to enable one-shot output on the OUTPUT signal.
X MENU mode-[SYS2]-[OUTPUT]-[ONE SHOT]
When one-shot output is set to [ON], the OFF delay time setting is disabled.
■ Setting the One-Shot output Time
OUTPUT turns ON for the preset time from when the OUTPUT signal turns ON.
This setting is valid only when [ONE SHOT] is set to [ON].
X MENU mode-[SYS2]-[OUTPUT]-[OUTPUT TIME]
Setting the ON Delay Time
Set this item to delay the timing that the OUTPUT signal turns ON.
X MENU mode-[SYS2]-[OUTPUT]-[ON DELAY]
Setting Details
OFF (default) One-shot output is not performed.
ON One-shot output is performed.
Setting Details
0 to 255 (default: 0) Set the time (ms) that OUTPUT is turned ON.
Setting Details
0 to 255 (default: 0) Set the time (ms) to delay turning OFF of the OUTPUT signal.
OFF
ON
OUTPUT
Judgment NG
Judgment OK Judgment NG
Delay time
OUTPUT ON at OK judgment in continuous measurement