User Manual
104
Section 5 SETTING ADDITIONAL FUNCTIONS
ZFV-C
User’s Manual
Section 5
Setting USB/RS-232C Communication Specifications
● RS-232C cable for connecting a personal computer
• ZS-XRS2 (cable length: 2 m)
■ Setting communication specifications
Set the communication specifications of the Amplifier Unit according to those of exter-
nal devices.
X MENU mode-[SYS2]-[COM]
Setting Description
LENGTH 7, 8 (default)
PARITY OFF (default), ODD, EVEN
STOP BIT 1 (default), 2
BAUDRATE 9600, 19200, 38400 (default), 57600, 115200
NODE 0 (default) to 16
Node No. indicates a connection group No. viewed from a host device (programmable
controller). Not only ZFV-C but also two or more devices can be connected to the pro-
grammable controller. Numbers assigned to the devices connected to the programma-
ble controller are called node Nos.
DELIMIT CR (default), LF, CR+LF
Amplifier unit side PC side (PC/AT compatible) (Note 1)
12 3 45
67 89
10 1
Fitting section
1NC
2 RD(RXD)
3 SD(TXD)
4NC
5 SG(GND)
6NC
7 RS(RTS)
8 CS(CTS)
9NC
1
NC
2
SD(TXD)
3
RD(RXD)
4
RS(RTS)
5
CS(CTS)
6
NC
7
NC
8
NC
9
SG(GND)
NC
10
Signal name
Signal name
Pin No.
Pin No.
Note 1: A socket type connector
is used for the PC side.