User Manual

Section 5 SETTING ADDITIONAL FUNCTIONS
Section 5
Setting USB/RS-232C Communication Specifications
103
ZFV-C
User’s Manual
RS-232C Connection
Connection
1. Insert one end of the RS-232C cable to
the RS-232C connector on the Amplifier
Unit.
2. Insert the other end of the RS-232C cable
to the RS-232C connector of the external
device.
RS-232C cable for connecting a programmable controller
RS-232C cable
ZS-XPT2 (cable length: 2 m)
10 1
Fitting section
12 3 45
6789
1NC
2 SD(TXD)
3 RD(RXD)
4 RS(RTS)
5 CS(CTS)
6NC
7NC
8NC
9 SG(GND)
1
NC
2
SD(TXD)
3
RD(RXD)
4
RS(RTS)
5
CS(CTS)
6
NC
7
NC
8
NC
9
SG(GND)
NC
10
Signal name
Signal name
Pin No.
Pin No.
Amplifier unit side PLC side (Note 1)
Note 1: A plug type connector is