User Manual
Section 5 SETTING ADDITIONAL FUNCTIONS
Section 5
Setting the System Environment
97
ZFV-C
User’s Manual
Selecting the Measurement Timing
Set the timing that measurement is executed.
X MENU mode-[SYS1]-[MEAS TYPE]
Selecting the Teaching Mode from an External Device
There are two teaching modes from an external device.
X MENU mode-[SYS1]-[TEACH TYPE]
Timing Charts p.42
Setting Screen Display
The color of characters displayed on the LCD monitor and monitor’s background color can
be changed. Change the color when it is difficult to see the character or figure on the
image.
• Areas whose color can be changed
X MENU mode -[SYS1]-[DISP COL]
Setting Details
TRIG (default) Synchronous measurement
Measurement is performed in synchronous with the change in state of the exter-
nal TRIG signal from OFF to ON.
CONTINUE Continuous measurement
Measurement is repeatedly performed for the duration that the TRIG signal is ON.
Setting Details
STATIONARY (default) Teaching is performed with the workpiece in a stationary state. Input of the
external trigger is required for teaching.
MOVING The teaching is performed with the moving workpiece.
Select this teaching mode only when the workpiece cannot be stopped.
Input of the external trigger is required for teaching.
Setting
OK GREEN (default), RED, YELLOW, BLUE, WHITE
NG GREEN, RED (default), YELLOW, BLUE, WHITE
NORMAL GREEN, RED, YELLOW, BLUE, WHITE (default)
BACK GREEN, RED, YELLOW, BLUE (default), WHITE, BLACK
+
SEARCH
OK
SYS1/DISP COL
1.OK
2.NG
3.DISP NRML
4.DISP BACK
OK/NG
NORMAL
BACK
NORMAL (color of characters)