User Manual
Section 4 SETTING OF INSPECTION CONDITION
Section 4
Inspecting by Width (WIDTH)
73
ZFV-C
User’s Manual
■ Adjusting the threshold level
CUSTOM Menu
Items that can be customized
Setting item Range Details of Adjustment
Edge width 0 to 999 This is the range for OK when the width at teaching is taken to be 100 %.
Edge level 0 to 100 This is the density level judged to be an edge.
Adjust this level when measurement is unstable.
Items that can be customized Page
Items related to
edge detection
Selecting the color of edge p.74
Selecting the edge detection direction p.74
Items related to
color
Changing the color mode (default: FILTER) p.74
Changing the filter color (only when [FILTER] is selected in [COL MODE]) p.65
Teaching Brightness (only when [PICKUP] is selected in [COL MODE]) p.65
ADJ
RUNMENU
WIDTH
OK
120
L: [ 100] H:[ 150]
WIDTH
OK
EDGE LEV [ 50]
:LEV :SEL
● Adjustment of
edge width
● Switching to
ADJ mode
Measured
values
● Adjustment of
edge width
Upper/lower limit
Lower limit Upper limit
Edge level
LEFT/RIGHT keys: Select upper limit/lower limit.
UP/DOWN keys: Change values.
LEFT/RIGHT keys: Switch edge.
UP/DOWN keys: Change values.
Edge level
• When edge detection direction is ←→
UP/DOWN keys: Switch edge.
LEFT/RIGHT keys: Change values.
• When edge detection direction is ↑↓
Teaching area
Max. density value
Edge level
Min. density value