Section 4 SETTING OF INSPECTION CONDITION
ZFV-C
User’s Manual
Section 4
Inspecting by Pattern (PATTERN)
CUSTOM Menu
Items that can be customized
Items related to pattern
Changing the search area
Change the area to search the model in. Specify the top left and bottom right of the
search area.
X MENU mode-[TEACH] -[CUSTM] -[SEARCH AREA]
Setting the rotation range of a workpiece (only when [SEARCH] is selected)
Set this item when even a tilted workpiece is to be set as a non-defective item.
X MENU mode-[TEACH]-[CUSTM]-[ROTATION]
Items that can be customized Page
Items Related to
pattern
Changing the search area p.64
Setting the rotation range of a workpiece (only when [SEARCH] is selected) p.64
Items related to
color
Changing the filter color p.65
Performing color check p.65
Teaching brightness p.65
Setting Details
±10° (default), ±20°, ±30°, ±45° Set the range of acceptable tilt.
The wider the rotation range, the longer the measurement time.
ABCDE
Search area
Model