User Manual
110
Section 5 SETTING ADDITIONAL FUNCTIONS
ZFV-C
User’s Manual
Section 5
Setting for Amplifier Unit Gang-Mount
Setting for Amplifier Unit Gang-Mount
The gang-mount related menus are displayed only when Amplifier Unit are gang-mounted.
These settings must be made to each Amplifier Unit.
● Example 1: 1 sensor head + multiple amplifier units
Example of detection of input image from 1 sensor head with multiple amplifier units.
• To detect multiple areas such as a 4-sided POSITION, multiple item SEARCH, etc.
• To detect multiple types such as both SEARCH and AREA judgments.
● Example 2: Multiple sensor heads + multiple amplifier units
Example of synchronizing and detecting multiple points of the same workpiece and
integrating judgments.
MENU AMP1/2 AMP3
TRIG LINK I/O
HEAD NOTUSE USE
LINKOUT – All
MENU AMP1/2 AMP3
TRIG LINK I/O
HEAD USE USE
LINKOUT – All
AMP1 AMP2 AMP3
TRIG signalENABLE signal
Images are transferred
from right-side to left-
side amplifier units.
AMP1 AMP2 AMP3
Measured with
images loaded from
each sensor head.
TRIG signalENABLE signal