User Manual
Section 5 SETTING ADDITIONAL FUNCTIONS
Section 5
Changing OUTPUT Signal Output Conditions
109
ZFV-C
User’s Manual
Setting the OFF Delay Time
Set this item to delay the timing that the OUTPUT signal turns OFF.
X MENU mode-[SYS2]-[OUTPUT]-[OFF DELAY]
Setting Details
0 to 255 (default: 0) Set the time (ms) to delay turning OFF of the OUTPUT signal.
OFF
ON
OUTPUT
Judgment NG
Judgment OK Judgment NG
Delay time
OUTPUT ON at OK judgment in continuous measurement