Datasheet

2
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Mounting
Side mounting Base mounting Diagonal side mounting
Actuator Model
Approved
standards
Model
Approved
standards
Model
Approved
standards
UL
CSA
UL
CSA
UL
CSA
General
purpose
Plunger
AC ZE-Q-2 ●●ZV-Q-2 ●●ZV2-Q-2 ●●
DC XE-Q-2 XV-Q-2 XV2-Q-2
Roller plunger
AC ZE-Q22-2 ●●ZV-Q22-2 ●●ZV2-Q22-2 ●●
DC XE-Q22-2 XV-Q22-2 XV2-Q22-2
Crossroller plunger
AC ZE-Q21-2 ●●ZV-Q21-2 ●●ZV2-Q21-2 ●●
DC XE-Q21-2 XV-Q21-2 ---
Roller arm lever
AC ZE-QA2-2 ●●ZV-QA2-2 ●●ZV2-QA2-2 ●●
DC XE-QA2-2 XV-QA2-2 XV2-QA2-2
One-way action roller
arm lever
AC ZE-QA277-2 ●● --- ZV2-QA277-2 ●●
DC XE-QA277-2 --- ---
Sealed
(Booted)
Sealed plunger
AC ZE-N-2 ●●ZV-N-2 ●●ZV2-N-2 ●●
DC XE-N-2 XV-N-2 XV2-N-2
Sealed roller plunger AC ZE-N22-2 ●●ZV-N22-2 ●●ZV2-N22-2 ●●
Sealed crossroller
plunger
AC ZE-N21-2 ●●ZV-N21-2 ●●ZV2-N21-2 ●●
Sealed roller arm lever
AC ZE-NA2-2 ●●ZV-NA2-2 ●●ZV2-NA2-2 ●●
DC XE-NA2-2 XV-NA2-2 XV2-NA2-2
One-way action
sealed roller arm lever
AC ZE-NA277-2 ●●ZV-NA277-2 ●●ZV2-NA277-2 ●●
DC XE-NA277-2 --- XV2-NA277-2
Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No.14 LR45746
CCC (CQC) GB14048.5 2003010303077623
Model
Rated
voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
ZE-@
ZV-@
ZV2-@
125 VAC
250 VAC
480 VAC
15
15
10
3
2.5
1.5
1.5
1.25
0.75
15
15
6
5
3
1.5
2.5
1.5
0.75
125 VDC
250 VDC
0.5
0.25
0.5
0.25
0.05
0.03
0.05
0.03
XE-@
XV-@
XV2-@
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
10
10
3
3
3
3
3
1.5
1.5
1.5
1.5
1.5
0.75
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
2.5
2.5
2.5
2.5
1.5
Inrush
current
NC 30 A max.
NO 15 A max.
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.