Datasheet

2
ZC-@55
Specifications
Approved Standards
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
Ratings
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions
according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
Approved Standard Ratings
UL/CSA
A300
TÜVRheinland (EN60947-1, EN60947-5-1),
CCC (GB14048.5)
Characteristics
*1. Only for models with plungers. (Contact your OMRON representative for
information on other models.)
*2. Less than 1 ms under a free state at the operating limits.
Engineering Data
Electrical Durability
Mechanical Durability (for ZC-Q55)
Agency Standard File No.
UL* UL508 E76675
TÜV Rheinland EN60947-1, EN60947-5-1 J50041904
CCC(CQC) GB14048.5 2003010303077620
Rated
voltage
Non-inductive load (A) Inductive load (A)
Resistive load
Lamp load
Inductive load
Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
10
10
3
2.5
1.5
1.25
10
10
5
3
2.5
1.5
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
6
0.5
0.25
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
6
6
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03
Inrush
current
NC 30 A max.
NO 15 A max.
Voltage
Carry
current
Current (A)
Volt-amperes
(VA)
Make Break Make Break
120 VAC
240 VAC
10A
60
30
6
3
7,200 720
Applicable category and ratings
AC-12 10 A/250 VAC
Degree of protections IP67
Durability
Mechanical 10,000,000 operations min.
Electrical 500,000 operations min.
Operating speed 0.05 mm/s to 0.5 m/s *1
Operating
frequency
Mechanical 120 operations/min
Electrical 20 operations/min
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance
15 m max. (initial value for the built-
in switch when tested alone)
Dielectric
strength
Between non-continu-
ous terminals
1,000 VAC, 50/60 Hz for 1 min
Between each terminal
and non-current-carry-
ing metal parts
2,000 VAC, 50/60 Hz for 1 min
Rated insulation voltage (Ui) 1,000 VAC
Pollution degree
(operating environment)
3 (IEC947-5-1)
Short-circuit protective device 10 A-fuse type gG (IEC 60269)
Protection against electric shock Class II
Proof tracking index (PTI) 175
Switch category D (IEC335)
Rated operating current (Ie) 10 A
Rated operating voltage (Ue) 250 VAC
Vibration
resistance
Malfunction
10 to 55 Hz, 1.5-mm double ampli-
tude *2
Shock
resistance
Destruction 1,000 m/s
2
max.
Malfunction
300 m/s
2
max.
(in case of plunger model) *1 *2
Ambient operating temperature 10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight
Approx. 92 g (in case of ZC-
Q22(21)55)
10,000
Durability (×10
4
operations)
3,000
5,000
7,000
1,000
300
100
30
50
70
500
700
10
20 4 6 8 10 12
Switching current (A)
Operating temperature: +20
±
2°C
Operating humidity: 65
±
5%RH
Operating frequency: 20 operations/min
125 VAC cosφ=1
125 VAC cosφ=0.4
250 VAC cosφ=1
250 VAC cosφ=0.4
10,000
3,000
5,000
7,000
1,000
300
100
30
50
70
0.10 0.3 0.50.7 1 3 5 7 10
Operating temperature: +20
±
2˚C
Operating humidity: 65
±
5%RH
No load
Operating frequency: 120 operations/min
500
700
Durability (×10
4
operations)
OT (mm)