Datasheet

15
Z
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
49.2
11.9
25.4
±0.1
23.3
±0.25
OP
PT
8.35 dia.
11.9SR
*1
*1. Stainless-steel plunger
*2. Two hexagonal nuts (2 t
× 14 width across flats)
*3. Two lock nuts (2 t
× 15.6 width across flats)
*4. Incomplete screw part with a maximum length of 1.5 mm.
*4
16.3
13.1
*2
*3
M12
× 1
Mounting
screw
9.2
17.45
±0.2
4.2
+0.075
-0.025
4.2 dia. hole
+0.075
-0.025
4.36 dia.
+0.1
-0.05
16 dia.
Panel Mount Plunger
Z-15GQ55-B
Note: Do not use the M12
mounting screw and the
case mounting hole at
the same time, or the
case may be damaged.
OF max.
RF min.
PT max.
OT min.
MD max.
5.30 N
1.12 N
1.8 mm
5.5 mm
0.06 mm
OP 21.8±0.8 mm
49.2
11.9
25.4
±0.1
23.3
±0.25
OP
PT
*1. Stainless-steel roller
*2. Two hexagonal nuts (3 t
× 17 width across flats)
*3. Incomplete screw part with a maximum length of 1.5 mm.
*3
16.3
15.5
*2
12.7 dia.
× 4.8 *1
M12
× 1
mounting screw
9.2
17.45
±0.2
4.2
+0.075
-0.025
4.2 dia. hole
+0.075
-0.025
4.36 dia.
+0.1
-0.05
16 dia.
Panel Mount Roller Plunger
Z-15GQ2255-B
Note: Do not use the M12
mounting screw and the
case mounting hole at
the same time, or the
case may be damaged.
OF max.
RF min.
PT max.
OT min.
MD max.
5.30 N
1.12 N
1.8 mm
3.58 mm
0.06 mm
OP 33.4±1.2 mm
17.45
±0.2
4.2
+0.075
-0.025
4.2 dia. hole
+0.075
-0.025
4.36 dia.
+0.1
-0.05
49.2
11.9
25.4
±0.1
23.3
±0.25
OP
PT
*1. Stainless-steel roller
*2. Two hexagonal nuts (3 t
× 17 width across flats)
*3. Incomplete screw part with a maximum len
g
th of 1.5 mm.
*3
16.3
15.5
*2
12.7 dia.
× 4.8 *1
16 dia.
M12 × 1
mounting
screw
9.2
Panel Mount Cross Roller Plunger
Z-15GQ2155-B
Note: Do not use the M12
mounting screw and the
case mounting hole at
the same time, or the
case may be damaged.
OF max.
RF min.
PT max.
OT min.
MD max.
5.30 N
1.12 N
1.8 mm
3.58 mm
0.06 mm
OP 33.4±1.2 mm
49.2
11.9
25.4
±0.1
49.6
±0.8
23.9
OP
FP
4.8
* Stainless-steel spring lever
t = 0.3 *
9.2
17.45
±0.2
4.2
+0.075
-0.025
4.2 dia. hole
+0.075
-0.025
4.36 dia.
+0.1
-0.05
Leaf Spring
Z-15GL55-B
* When operating, be sure not to
exceed 1.6 mm.
OF max.
RF min.
OT *min.
MD max.
1.96 N
0.14 N
1.6 mm
1.3 mm
FP max.
OP
20.6 mm
17.5±0.8 mm