Datasheet

General-purpose Basic Switch Z 153
Z-15 (Flexible Rod Models)
Z-10F
Z-01H
Applicable Load Range
■ Contacts Specification
■ Safety Standards Ratings
UL/CSA (General ratings only)
TÜV (EN61058-1)
Note: 1. The above current ratings are the values of the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The normally closed and normally open ratings of reverse hinge
lever models are opposite to each other.
6. The AC ratings of molded terminals are 125 and 250 V only.
7. The ratings values apply under the following test conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
8. Consult Omron regarding CCC standards and ratings.
Rated voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
15
15
2
1
1
0.5
7
5
2.5
1.5
2
1
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
15
15
2
0.4
0.2
2
2
2
0.4
0.2
1
1
1
0.4
0.2
7
7
1
0.03
0.02
3
3
1
0.03
0.02
1.5
1.5
0.5
0.03
0.02
Item
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
Contact gap
Rated
voltage
NC NO NC NO NC NO NC NO
Series
connection
125 VAC
250 VAC
10
10
4
2.5
2
1.5
6
6
5
3
2.5
1.5
30 VDC
125 VDC
250 VDC
10
1
0.6
4
1
0.6
2
1
0.6
6
0.1
0.05
6
0.1
0.05
3
0.1
0.05
Parallel
connection
125 VAC
250 VAC
6
6
3
2.5
1.5
1.25
4
4
4
2
2
1
30 VDC
125 VDC
250 VDC
6
0.6
0.3
4
0.6
0.3
2
0.6
0.3
4
0.1
0.05
6
0.1
0.05
3
0.1
0.05
Rated voltage
Resistive load (A)
NC NO
125 VAC 0.1
8 VDC
14 VDC
30 VDC
0.1
0.1
0.1
Z-01H
Z-15
@
, Z-10FY
Minimum applicable load 1 mA at 5 VDC 160 mA at 5 VDC
30
24
12
5
0
1 10 100 1,000
Current (mA)
0.1
1 mA
Standard load
area
Z-15H, H2
Z-15G
Z-15E
Z-10FY
Z-15ER
Micro load area
Z-01H
26 mA0.16 mA
800 mW5 mW
100 mA 160 mA
Unusable
range
Voltage (V)
Item Classification Z-15 Z-01H Z-10F
Contacts
Shape Rivet
Single
crossbar
Rivet
Material Silver Gold alloy Silver
Inrush current
NC 30 A max. 0.1 A max. 40 A max.
NO 15 A max. 0.1 A max. 20 A max.
Rated
voltage
Model Z-15 Z-10F Z-01H
125 VAC 15A and 1/8HP 6A and 1/10HP 0.1A
250 VAC 15A and 1/4HP 6A and 1/8HP ---
480 VAC 15A 6A ---
30 VDC --- --- 0.1A
125 VDC 0.5A 0.6A ---
250 VDC 0.25A 0.3A ---
Rated
voltage
Model Z-15H@-B Z-15G@-B Z-01H@-B
250 VAC 15 A 15 A ---
125 VAC --- --- 0.1 A
30 VDC --- --- 0.1 A