Datasheet

H3Y
6
Engineering Data
Connections
Connections
H3Y-2, H3Y-2-0
Switching operations (×10
4
)
Load current (A)
H3Y-2, H3Y-2-0
H3Y-4, H3Y-4-0
Load current (A)
Load current (A)
H3Y-4, H3Y-4-0
Load current (A)
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected.The minimum
applicable load is 1 mA at 5 VDC (P reference value).
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected.The minimum
applicable load is 1 mA at 1 VDC (P reference value).
Switching operations (×10
4
)
Switching operations (×10
4
)
Switching operations (×10
4
)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
20