Datasheet
XS2
32
Safety Precautions
Extraction Procedure
(1) Disconnecting Components
• Disconnect all components on the cap side from the cover.
(2) Extracting Pin Block
• Insert the claws of the Tool into the four holes of the cover.
• Make sure that the pin block is outside the Tool.
• Press the Tool so that the guides of the Tool are in close 
contact. Then pull the pin block straight.
• The pin block must not be extracted from the same 
Connector more than 3 times, otherwise the proper degree 
of protection of the pin block or Connector will not be 
maintained.
• Do not use the product in atmospheres or environments that 
exceed product ratings.
Tightening Cap (Connector Assemblies)
1) Do not use pliers to tighten caps, otherwise the caps may 
be damaged. Use your fingers to tighten the Connectors 
sufficiently.
(0.39 to 0.49 N·m)
2) If caps are not tightened securely, the Connectors may not 
maintain their proper degree of protection (i.e., IP67) or the 
caps may become loose due to vibration.
Connector Connection and Disconnection
• When connecting or disconnecting Connectors, be sure to 
hold the Connectors by hand.
• Do not hold the cable when disconnecting Connectors.
• Connectors mating with sockets must be fully inserted into 
the mating sections. Tighten the thread bracket carefully so 
that the threads will not be damaged.
• Fully tighten thread bracket within a torque range between 
0.39 and 0.49 N·m and be sure that the threads of the 
opposite parts are hidden by the thread bracket.
• When disconnecting Connectors, be sure to loosen the 
thread brackets first. Do not loosen the caps.
• Thread brackets must be loosened in the cutout direction.
Degree of Protection
• Do not impose external force continuously on the joints of 
pin blocks and covers, otherwise the Connectors may not 
keep its proper degree of protection (i.e., IP67).
• The degree of protection of connectors (IP67) is not for a 
fully watertight structure. Do not use them underwater.
• Connectors are of resin mold construction. Do not impose 
excessive force on them.
Setup
• Do not make any cable bends near the base of the Unit.
• Any bends made must have a minimum radius of 40 mm.
Pin block Cover Rubber
bushing
Cable clamp Cap
Holes
Claws
Tool
Pin block
Guide 
Cover 
Cover 
Pin block
Guide 
Extracting 
direction 
Precautions for Correct Use
Loosen
Cutout
Thread
bracket










