Datasheet
XS2
32
Safety Precautions
Extraction Procedure
(1) Disconnecting Components
• Disconnect all components on the cap side from the cover.
(2) Extracting Pin Block
• Insert the claws of the Tool into the four holes of the cover.
• Make sure that the pin block is outside the Tool.
• Press the Tool so that the guides of the Tool are in close
contact. Then pull the pin block straight.
• The pin block must not be extracted from the same
Connector more than 3 times, otherwise the proper degree
of protection of the pin block or Connector will not be
maintained.
• Do not use the product in atmospheres or environments that
exceed product ratings.
Tightening Cap (Connector Assemblies)
1) Do not use pliers to tighten caps, otherwise the caps may
be damaged. Use your fingers to tighten the Connectors
sufficiently.
(0.39 to 0.49 N·m)
2) If caps are not tightened securely, the Connectors may not
maintain their proper degree of protection (i.e., IP67) or the
caps may become loose due to vibration.
Connector Connection and Disconnection
• When connecting or disconnecting Connectors, be sure to
hold the Connectors by hand.
• Do not hold the cable when disconnecting Connectors.
• Connectors mating with sockets must be fully inserted into
the mating sections. Tighten the thread bracket carefully so
that the threads will not be damaged.
• Fully tighten thread bracket within a torque range between
0.39 and 0.49 N·m and be sure that the threads of the
opposite parts are hidden by the thread bracket.
• When disconnecting Connectors, be sure to loosen the
thread brackets first. Do not loosen the caps.
• Thread brackets must be loosened in the cutout direction.
Degree of Protection
• Do not impose external force continuously on the joints of
pin blocks and covers, otherwise the Connectors may not
keep its proper degree of protection (i.e., IP67).
• The degree of protection of connectors (IP67) is not for a
fully watertight structure. Do not use them underwater.
• Connectors are of resin mold construction. Do not impose
excessive force on them.
Setup
• Do not make any cable bends near the base of the Unit.
• Any bends made must have a minimum radius of 40 mm.
Pin block Cover Rubber
bushing
Cable clamp Cap
Holes
Claws
Tool
Pin block
Guide
Cover
Cover
Pin block
Guide
Extracting
direction
Precautions for Correct Use
Loosen
Cutout
Thread
bracket