Datasheet
27
XS2
Features
XS2R Application Examples
Safety Precautions
Do not use the product in atmospheres or environments that exceed product ratings.
• Before using the XS2R for Sensors, make sure that the wiring of the Sensors and the internal connections of the XS2R are
correct.
Precautions for Correct Use
AB
C
SensorSensor
XS2W/XS2F/XS2C
XS2R-D422-1XS2G/XS2H XS2G/XS2H
Photoelectric sensor
Photoelectric sensor
AB
C
Sensor
XS2G/XS2H
XS2R-D423-1XS2W/XS2F/XS2C XS2W/XS2F/XS2C
Proximity sensor
PLC (A)
PLC (B)
Sensor2 Sensor3Sensor2
AB
C
AB
C
AB
C
Sensor1
• A pair of Two-wire Sensors or
Three-wire Sensors can be
connected as shown in the
illustration.
• The XS2R-D422-5 has feed through
connections, thus working as a
connector for the extension cable.
XS2R-D422-1 (Aggregate Model)
XS2R-D423-1 (Bifurcated Model)
• Two or Three-wire Sensor signals
can be bifurcated.
XS2R-D424-1 (Daisy Chain Model)
• Two-wire Sensors with contact
output can be connected through a
daisy chain to obtain AND output.