27
XS2
Features
XS2R Application Examples
Safety Precautions
Do not use the product in atmospheres or environments that exceed product ratings.
Before using the XS2R for Sensors, make sure that the wiring of the Sensors and the internal connections of the XS2R are
correct.
Precautions for Correct Use
AB
C
SensorSensor
XS2W/XS2F/XS2C
XS2R-D422-1XS2G/XS2H XS2G/XS2H
Photoelectric sensor
Photoelectric sensor
AB
C
Sensor
XS2G/XS2H
XS2R-D423-1XS2W/XS2F/XS2C XS2W/XS2F/XS2C
Proximity sensor
PLC (A)
PLC (B)
Sensor2 Sensor3Sensor2
AB
C
AB
C
AB
C
Sensor1
A pair of Two-wire Sensors or
Three-wire Sensors can be
connected as shown in the
illustration.
The XS2R-D422-5 has feed through
connections, thus working as a
connector for the extension cable.
XS2R-D422-1 (Aggregate Model)
XS2R-D423-1 (Bifurcated Model)
Two or Three-wire Sensor signals
can be bifurcated.
XS2R-D424-1 (Daisy Chain Model)
Two-wire Sensors with contact
output can be connected through a
daisy chain to obtain AND output.