Datasheet

23
XS2
(5) Mounting Cap
After mounting the cover to the pin block and the cover
snaps into place, tighten the cap securely by hand (0.39 to
0.49 N·m)
Note: If the cap is not tighten securely enough, the degree of protection (IP67)
may not be maintained or vibration may cause the cap to become loose.
Do not tighten the cap with pliers or similar tools; they may damage the
cap.
After fully tightening the cap, length A should be
approximately one of the following according to the cable
external diameter and the Connector model. (Use these as
a guide.)
(6) After Assembly
Confirm the insulation between cores after completing
assembly.
Recommended Cables
When connecting a commercially available cable to a
connector assembly, use a cable with an outside diameter of
3 to 6 mm and core conductor sizes of 0.18 to 0.75 mm
2
for
crimping connectors and 0.5 mm
2
maximum for soldering
connectors.
Connector Arrangement
For safety, when constructing a connection system between a
Sensor and panel with a connector, make sure that the
connector plug is on the Sensor side and the connector socket
is on the panel side (i.e., the female pins are located on the
power-supply side).
External diameter of
applicable cable
Cable external diameter (mm)
6 mm 5 mm 4 mm 3 mm
For 6-mm-dia. cable 10
For 4-mm-dia. cable —2 1—
For 3-mm-dia. cable —— 2 1
Cap
A
Sensor Side
Connecting Cable
Panel Side
(Power-supply Side)
(Plug)
(Socket)
(Plug) (Socket)