Datasheet

WL-N/WLM-N
49
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
Note: Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not necessary to
ensure a proper seal.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.
Conduit Applicable cable
Inner diameter (D)
of seal rubber
External diameter of cable
Model Applicable model
Min. Max.
JIS B 0202 G½
Cabtire cable (general-
purpose)
7 mm 5.5 mm 7.5 mm SC-1M
WL-N, D4A-@N, D4B-@N, ZE,
ZV, ZV2, XE, XV, XV2
9 mm 7.5 mm 9.5 mm SC-2M
12.5 mm 11 mm 13 mm SC-3M
14 mm 12 mm 14 mm SC-4M
11 mm 9 mm 11 mm SC-5M
Cabtire cable (anti-
corrosive)
7 mm 5.5 mm 7.5 mm SC-21
9 mm 7.5 mm 9.5 mm SC-22
12.5 mm 11 mm 13 mm SC-23
14 mm 12 mm 14 mm SC-24
11 mm 9 mm 11 mm SC-25
½-14NPT Cabtire cable
7 mm 5.5 mm 7.5 mm SC-1PT
D4A-@N
9 mm 7.5 mm 9.5 mm SC-2PT
12.5 mm 11 mm 13 mm SC-3PT
14 mm 12 mm 14 mm SC-4PT
11 mm 9 mm 11 mm SC-5PT
Conduit Applicable cable
Inner diameter (D)
of seal rubber
External diameter of cable
Model Applicable model
Min. Max.
JIS B 0202 G½
Cabtire cable
10.6 mm 8.5 mm 10.5 mm SC-P2
WL-N, D4A-@N, D4B-@N, ZE,
ZV, ZV2, XE, XV, XV2
Pg13.5 9.6 mm 7.5 mm 9.5 mm SC-P3 WL@-G-N
JIS B 0202 G½ 9 mm 7.5 mm 9 mm SC-6
WL-N, D4A-@N, D4N *,
D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2