Datasheet

3
TL-W
DC 3-Wire Models
* For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
Model
Item
TL-W1R5MC1 TL-W3MC@ TL-W5MC@
TL-W5E1, TL-W5E2
TL-W5F1, TL-W5F2
TL-W20ME1
TL-W20ME2
Sensing distance 1.5 mm ±10% 3 mm ±10% 5 mm ±10% 20 mm ±10%
Set distance 0 to 1.2 mm 0 to 2.4 mm 0 to 4 mm 0 to 16 mm
Differential travel 10% max. of sensing distance
1% to 15% of
sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing
object
Iron, 8 × 8 × 1 mm Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm
Iron, 50 × 50 ×
1mm
Response
frequency
1 kHz min. 600 Hz min. 500 Hz min. 300 Hz min. 40 Hz min.
Power supply volt-
age (operating volt-
age range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 20% max.
12 to 24 VDC (10
to 30 VDC), ripple
(p-p): 10% max.
Current
consumption
15 mA max. at 24 VDC (no-load) 10 mA max. 15 mA max. at 24 VDC (no-load)
8 mA at 12 VDC,
15 mA at 24 VDC
Control
output
Load
current
NPN open collector
100 mA max. at 30 VDC max.
NPN open collector
50 mA max. at
12 VDC (30 VDC
max.)
100 mA max. at
24 VDC (30 VDC
max.)
200 mA
100 mA max. at
12 VDC
200 mA max. at
24 VDC
Residual
voltage
1 V max. (under load current of 100 mA with
cable length of 2 m)
1 V max. (under load
current of 50 mA with
cable length of 2 m)
2 V max. (under load current of
200 mA with cable length of 2 m)
1 V max. (under
load current of
200 mA with ca-
ble length of 2 m)
Indicators Detection indicator (red)
Operation mode
(with sensing ob-
ject approaching)
NO
C1 Models: NO
C2/B2 Models: NC
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 6 for details.
Protection circuits Reverse polarity protection, Surge suppressor
Ambient
temperature range
Operating/Storage: 25 to 70°C (with no icing or condensation) *
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence
±2.5% max. of sensing distance at rated volt-
age in the rated voltage ±10% range
±2.5% max. of sens-
ing distance at rated
voltage in the rated
voltage ±20% range
±2.5% max. of sensing distance at rated voltage in
the rated voltage ±10% range
Insulation
resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s
2
3 times each in X, Y, and Z directions
Destruction:
500 m/s
2
10
times each in X,
Y, and Z direc-
tions
Degree of
protection
IEC 60529 IP67, in-house standards: oil-resistant *
Connection
method
Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state)
Approx. 70 g Approx. 80 g Approx. 100 g Approx. 210 g
Materi-
als
Case Heat-resistant ABS Aluminum die-cast
Heat-resistant
ABS
Sensing
surface
Heat-resistant ABS
Accessories Mounting Bracket, Instruction manual Instruction manual