Datasheet
S8BA
2
Ratings, Characteristics, and Functions
*1. An estimated value for standard mounting. Not a guaranteed value.
*2. Conditions: With rated loads connected, at a rated input voltage, and with the battery fully charged.
*3. Conditions: With rated loads connected, at a rated input voltage, and at the maximum battery charging current.
*4. 400 W for use as a UL compliant device.
*5. 20 A for use as a UL compliant device.
*6. 16.7 A for use as a UL compliant device.
*7. When using in an environment at a high temperature, charging may be paused by charging temperature protection, then the charging time will 
be longer than specified time.
"CS" will be displayed when charging temperature protection is operated.
*8. For the S8BA-24D24D120LF, install all of the RSMN-2030, RSHN-2030, and RSEN-2030 EMC filters manufactured by TDK. For the S8BA-
24D24D240LF, S8BA-24D24D360LF, or S8BA-24D24D480LF, install both the RSMN-2030 and RSHN-2030 or their equivalents. Install these 
filters in series to the cable connected to the DC input terminal block.
When you do, do not connect anything to the GR terminal.
The effectiveness of the noise filters may be affected by the installation environment. Be sure to check effectiveness before starting operation.
Item Capacity 120 W 240 W 360 W 480 W *4
DC input
Rated input voltage 24 VDC
Input 
voltage 
range
(When standard voltage 
sensitivity is set)
24 VDC±10%
(When low voltage 
sensitivity is set)
24 VDC±12.5%
(When high voltage 
sensitivity is set)
24 VDC±5%
Input 
maximum 
current
(for rated input voltage for 
rated loads connected)
5.9 A 11.7 A 17.5 A 23.3 A *5
Input terminal Push-in terminal block
Input protection Fuse
Input protection capacity 10 A 15 A 30 A
DC output
Rated 
current
(for rated output voltage) 5 A 10 A 15 A 20 A *6
Switching time Uninterrupted
Output 
voltage
Normal operation Output of input voltage as-is
Backup operation 24 V±5%
Output terminal Push-in terminal block
Overload protection
Alarm display at a load level of 110% or over (normal operation)
Alarm display at a load level of 110% or over and output voltage drop (backup operation)
Alarm display cancellation at a load equal to or below the rated capacity (normal operation, backup 
operation)
Battery
Type Lithium-ion battery
Rated voltage 14.4 VDC
Rated capacity 1600 mAh × 1 parallel 1600 mAh × 2 parallel 1600 mAh × 3 parallel 1600 mAh × 4 parallel
Expected battery life *1 2.5 years (50°C), 5 years (40°C), 10 years (25°C)
Replacement by user Yes (Hot swapping)
Auto battery check function Yes
Battery life counter function Yes
Charging time 4 hours *7
Backup time (25°C, initial characteristics) 6 min. (120 W) 6 min. (240 W) 6 min. (360 W) 6 min. (480 W)
Environment
Operating ambient temperature/humidity
0 to 55°C/10 to 90% (with no condensation)
Storage ambient temperature/humidity  –20 to 55°C/10 to 90% (with no condensation)
Vibration resistance
JIS C 60068-2-6 compliant. 5 to 8.4 Hz amplitude: 3.5 mm, 8.4 to 150 Hz acceleration rate: 9.8 m/s
2
X, Y, and Z directions for 100 minutes (Time coefficient: 10 minutes × coefficient factor 10 = total time 100 min.)
Shock resistance JIS C 60068-2-27 compliant. 147 m/s
2
, 3 times in X, Y, and Z directions.
Enclosure
Dimensions (W × D × H mm) 94 × 100 × 100 148 × 100 × 100 270 × 100 × 100
Weight of unit Approx. 0.8 kg Approx. 1.3 kg Approx. 2.0 kg Approx. 2.3 kg
Cooling method Natural cooling
Insulation and 
withstand 
voltage
Withstand voltage
1,000 V 50/60 Hz AC between the DC external terminals and the GR terminal for 1 minute at a leakage 
current of 10 mA max.
Insulation resistance 20 MΩ min. between the DC external terminals and the GR terminal (at 500 VDC)
Compliance 
to standard
Safety standard
UL508/CE/C22.2 No.107.1-01
EMI
Radiated disturbance 
electromagnetic field strength
EN61000-6-4/FCC/ICES/RCM/KC
Ship standard LR/ABS/EN60945 *8/DNV GL
Internal power consumption (normal *2 / maximum *3)
7 W/22 W 11 W/41 W 14 W/60 W 18 W/80 W
Serial 
communication
RS232C (Interface terminal) Yes (RJ45)
USB (interface terminal) Yes (B connector)
I/O signal Yes (RJ45)
Accessory functions
Beeper setting; Auto restart setting; Auto test setting; Auto restart mode setting; Input sensitivity setting; 
Remote ON/OFF signal logic setting; Cold start setting; Battery life counter setting; Power switch function 
setting; Maximum backup time setting; Startup battery level setting; Backup stop (BS) signal delay time 
setting; Backup (BU) signal delay time setting; and Contact signal I/O test










