Datasheet

H3Y
4
Specifications
Time Ranges
Ratings
*1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timers for details on your OMRON website.
*2. With DC ratings, single-phase full-wave rectified power sources may be used.
*3. Only the H3Y-2 and H3Y-2-0 Series include 12 VDC models.
*4. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient
operating temperature of 50°C.
*5. Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
*6. Refer to Safety Precautions for All Timers on your OMRON website when combining the Timer with an AC 2-wire proximity sensor.
*7. A diode to prevent reverse voltages is provided only on models with a DC power supply.
Rated time Time setting range Rated time Time setting range
0.5 s 0.04 to 0.5 s 3 min 0.1 to 3 min
1 s 0.1 to 1 s 5 min 0.2 to 5 min
5 s 0.2 to 5 s 10 min 0.5 to 10 min
10 s 0.5 to 10 s 30 min 1 to 30 min
30 s 1.0 to 30 s 60 min 2 to 60 min
60 s 2.0 to 60 s 3 h 0.1 to 3 h
120 s 5.0 to 120 s --- ---
Item H3Y-2(-0)/H3Y-4(-0)
Rated supply voltage *6, *7
100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz), 24 VAC (50/60 Hz) *1
12, 24, 48, 125, 100 to 110 VDC *2, *3
Operating voltage range
All rated voltages except 12 VDC: 85% to 110% of rated supply voltage
12 VDC: 90% to 110% of rated supply voltage *4
Reset voltage 10% min. of rated supply voltage *5
Power consumption
100 to 120 VAC: 1.5 VA (at 120 VAC)
200 to 230 VAC: 1.8 VA (at 230 VAC)
24 VAC: 1.5 VA (at 24 VAC)
12 VDC: 0.9 W (at 12 VDC)
24 VDC: 0.9 W (at 24 VDC)
48 VDC: 1.0 W (at 48 VDC)
100 to 110 VDC: 1.3 W (at 110 VDC)
125 VDC: 1.3 W (at 125 VDC)
Control outputs
H3Y-2(-0):
5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag
H3Y-4(-0):
3 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 1 VDC (P reference value).
Contact materials: Au-clad + Ag-alloy
Ambient operating temperature -10°C to 50°C (with no icing)
Storage temperature -25°C to 65°C