Datasheet
G2RV-SR
G2RV-SR G3RV-SR
Common AccessoriesCommon Precautions
6
Approved standards
UL508 (file No.E41643)
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).
TÜV (EN 61810-1)
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).
Engineering Data
Endurance curve (N.O. side) Switching capacity of DC resistive load
Model No. of poles Operation coil ratings Contact ratings Operations
G2RV-SR series
SPDT
12 to 48 VDC
24 to 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive
load)*
6,000
12 mm 12 mm 12 mm
Model No. of poles Operation coil ratings Contact ratings Operations
G2RV-SR series
SPDT
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive
load)*
50,000
50,000
6,000
12 mm 12 mm 12 mm
10
100
1000
024
Opening and closing current (A)
6
250 VAC resistive load
30 VDC resistive load
30 VDC
resistive load
250 VAC resistive load
Number of operations (x 10
3
operations)
0.1
1.0
10.0
20 60 100 140 180 220
DC switching voltage (V)
DC breaking current (A)