Datasheet

G2RV-SR
G2RV-SR G3RV-SR
Common AccessoriesCommon Precautions
5
Specifications
Ratings
Coil ratings
Note: The operating characteristics are measured at ambient temperature of 23°C.
* Operating voltage will be, for mounting in the upside down direction, 85% max.
Contact ratings
*1. P level: 60=0.1×10
-6
/times
This value is the value in switching frequency 120 operations/min.
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.
Characteristics
Note: Above values are initial values.
* Value is at ambient temperature of 23°C.
Rated input
voltage
Rated current
Must operate
voltage
Must release
voltage
Power consumption
Maximum
allowable voltage
AC
DC Percentage of the rated voltage AC (VA) DC (mW)
Percentage of the
rated voltage
50 Hz 60 Hz
12 VDC 27.9 mA
80% max.* 10% min.
Approx. 300 mW
110%
24 VDC 13.5 mA
Approx. 300 mW
24 VAC/VDC 12.5 mA 12.6 mA 12.6 mA
Approx. 0.5 VA
Approx. 300 mW
48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA
Approx. 0.4 VA
Approx. 250 mW
100 VAC 5.9 mA 6.0 mA
Approx. 0.8 VA
110 VAC 5.9 mA 5.9 mA
Approx. 0.8 VA
200 VAC 3.6 mA 4.3 mA
Approx. 1.7 VA
230 VAC 3.8 mA 4.5 mA
Approx. 1.7 VA
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP) *2
Contact configuration SPDT
Load
Resistive load
(cos=1)
Inductive load
(cos=0.4, L/R=7ms)
Resistive load
(cos=1)
Rated load
6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated carry current 6 A 50 mA
Maximum switching voltage 440 VAC, 125 VDC 30 VAC, 36 VDC
Maximum switching current 6 A 50 mA
Maximum switching power
1,500 VA
180 W
500 VA
60 W
Failure rate P value
(reference value) *1
10 mA at 5 VDC 1 mA at 100 mVDC
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP)
Contact resistance * 100 m max.
Operate (Set) time * 20 ms max.
Release time *
AC, AC/DC: 40 ms max.
DC: 20 ms max.
Maximum operating frequency
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Insulation resistance 1,000 M min. (at 500 VDC)
Dielectric strength
Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: Energized 200m/s
2
, Non-energized 100m/s
2
Endurance *
Mechanical 5,000,000 operations min.
Electrical
NO contact: 70,000 operations min.
NC contact: 50,000 operations min.
5,000,000 operations min.
Ambient operating temperature Operating: –40 to +55°C (with no icing or condensation)
Ambient operating humidity Operating: 5 to 85% RH
Weight Approx. 30 g
Contact material Ag alloy Ag alloy + Au plating