Common Options (Order Separately)
Common Precautions
Latching Relays (MYK)
For applications that use a 200 VAC power supply, connect
external resistors Rs and Rr to a 100 VAC Relay.
Do not apply a voltage to the set and reset coils at the same time.
If you apply the rated voltage to both coils simultaneously, the
Relay will be set.
The minimum pulse width in the performance column is the value
for the following measurement conditions: an ambient temperature
of 23°C with the rated operating voltage applied to the coil.
Satisfactory performance may be unattainable due to decreased
holding strength caused by changes in circuit conditions and
ambient operating temperature, or due to changes caused by
product aging.
During actual use, apply a pulse width of the rated operating
voltage suitable for the actual load to the coil and reset this at least
once per year as a means of dealing with product aging.
Hermetically Sealed Relays (MYH/MYQ)
Relays with PCB Terminals
When a Relay with PCB Terminals is mounted, a short-circuit can
occur depending on the design of the PCB pattern because the Relay
itself is made out of metal.
Solution
Refer to the external dimensions of the Relay and design the PCB
pattern with enough space to prevent this problem.
Application Environments
Humid environments can cause insulation problems, which may
result in short-circuiting or unintended operation.
Solution
Do not use these Relays in any environment where the Relay will
come into contact with water vapor, condensation, or water droplets.
This can reduce the surface tension of the terminal insulating beads
and cause short-circuiting or unintended operation due to insulation
problem.
Optional Sockets (Order Separately)
Be sure to read the Safety Precautions for All Relays in the website at the following URL:
http://www.ia.omron.com/product/cautions/36/safety_precautions.html
Front-connecting Sockets
Push-In Plus Terminal Sockets (PYF-08-PU(-L), PYF-14-PU(-L))
Refer to Safety Precautions on the Push-In Plus Terminal Block Socket PYF-@@-PU/P2RF-@@-PU Data Sheet (Catalog No. SGFR-218).
Screwless Terminal Sockets (PYF08S, PYF14S)
Refer to Safety Precautions on the Screwless Terminal Socket PYF@@S/P2RF-@@S Data Sheet (Catalog No. CDRR-011).
Screw Terminal Sockets (PYFZ-08(-E), PYF08A(-E), PYF08M, PYF11A, PYFZ-14(-E), PYF14A(-E), PYF-14T)
Be sure to read the Safety Precautions for All Relays, 4-2-1 Panel-mounting Sockets and 4-2-2 Relay Removal Direction of the website at the
following URL: http://www.ia.omron.com/product/cautions/36/safety_precautions.html
Back-connecting Socket
Solder Terminal Sockets (PY08(-Y1/-Y3), PY11(-Y1/-Y3))
Wrapping Terminals Sockets (PY08QN(-Y1/-Y3), PY08QN2(-Y1/-Y3), PY11QN(-Y1), PY11QN2(-Y1))
PCB Terminal Sockets (PY08-02, PY11-02)
Be sure to read the Safety Precautions for All Relays, 4-2-3 Back-connecting Sockets and 4-2-5 Terminal Soldering of the website at the
following URL: http://www.ia.omron.com/product/cautions/36/safety_precautions.html
14
Rr
Rs
Rs: 7.3 kΩ, 3 W min.
Rr: 14.3 kΩ, 1 W min.
Reset power supply
Set power supply
13
9101112