Miniature Power Relays Best-selling, general-purpose relays that can be selected based on operating environment and application MY MY/MYK/MYQ·MYH LR MYK • In addition to our standard type (MY), an abundant lineup of models including latching relays that retain contact operation status (MYK) and sealed relays suitable for environments where dust and corrosive gases are present (MYQ/MYH) are also available.
MY/MYK/MYQ·MYH Model List Miniature Power Relays: MY Plug-in terminals PCB terminals MY With operation indicator Classification Number of poles Contacts 2 Standard models 3 (compliant with Electrical Appliances and Material Safety Act) 4 MYK Models with built-in 2 diode for coil surge absorption 3 (compliant with Electrical Appliances and Material Safety Act) 4 Models with built-in CR 2 circuit for coil surge absorption (compliant with Electrical Appliances 4 and Material Safety Act) Case-surface m
Miniature Power Relays MY LR • AC/DC coil voltage specifications can now be more easily distinguished thanks to the use of color-coded coil tape and operation indicators (LED). • Latching levers convenient for circuit checking and MY(S) models equipped with mechanical operation indicators and operation indicators for monitoring operation status are available. • Contact materials and contact structures can be selected based on contact reliability and corrosion resistance.
MY Model Number Structure Model Number Legend ●Plug-in Terminals MY Standard models M Y (Example: MY4ZIN(S)) (1) (1) Number of poles (2) (3) (2) Contacts 2: 2-pole 3: 3-pole 4: 4-pole (3) Options None: Single Z: Bifurcated Z-CBG: Crossbar bifurcated None: None N: With operation indicator IN(S): With operation indicator/latching lever Models with built-in diode for coil surge absorption MYK M Y (Example: MY4ZIN-D2(S)) (1) (1) Number of poles/contacts 2: 2Z: 3: 4: 4Z: (2) (2) Options 2-
MY Ordering Information When your order, specify the rated voltage.
MY With operation indicator Classification MY Number of poles Contacts Single Model MY2N 2 Bifurcated Standard models (compliant with Electrical Appliances and Material Safety Act) 3 4 Single MY3N Single MY4N Bifurcated MYK Crossbar bifurcated Models with built-in diode for coil surge absorption (DC coil specification only) Models with built-in CR circuit for coil surge absorption (AC coil specification only) 2 3 4 2 4 Single MY4ZN MY4ZN-CBG 12, 24, 100/110, 110/120, 200/220, 220/240 VAC
MY ●PCB terminals Classification Contacts 2 Single MY2-02 3 Single MY3-02 Single MY4-02 Model 4 Bifurcated MY4Z-02 Rated voltage 12, 24, 100/110, 110/120, 200/220, 220/240 VAC 12, 24, 48, 100/110 VDC MY Standard models (compliant with Electrical Appliances and Material Safety Act) Number of poles 12, 24, 100/110, 110/120, 200/220, 220/240 VAC 12, 24, 48, 100/110 VDC 12, 24, 100/110, 110/120, 200/220, 220/240 VAC 12, 24, 48, 100/110 VDC 100/110, 110/120, 200/220 VAC 12, 24, 48, 100/110 VDC
MY Ratings and Specifications Ratings Operating Coils MY Terminal Type Classification Standard models Plug-in terminals Models with built-in diode for coil surge absorption (DC coil specification only) MYK Rated voltage (V) AC DC Rated current (mA) Contacts 2 Single MY2 Single MY4 MY4N Bifurcated MY4Z MY4ZN Single MY2-D MY2N-D2 Single MY4-D MY4N-D2 Bifurcated MY4Z-D MY4ZN-D2 Single MY2-CR MY2N-CR Single MY4-CR MY4N-CR MY4Z-CR MY4ZN-CR 4 Models with built-in CR circui
MY Terminal Type Classification Plug-in terminals Item AC 60 Hz With latching lever MY2IN(S) Single MY4IN(S) Bifurcated 4 MY4ZIN(S) Single MY2IN-D2(S) Single MY4IN-D2(S) Bifurcated MY4ZIN-D2(S) 2 Single MY4IN-CR(S) 4 Bifurcated Coil resistance (Ω) MY4ZIN-CR(S) Coil inductance (H) Armature OFF Armature ON 100/110 11.7/12.9 10/11 3,750 14.54 24.6 200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07 160 0.73 1.37 12 75 24 37.7 636 3.2 5.72 48 18.8 2,560 10.
MY Contact Ratings MY Number of poles (contact configuration) 2-pole (DPDT) Contact structure Load Single Resistive load Rated load 5 A at 220 VAC 5 A at 24 VDC Rated carry current*1 5 A (10 A*2) 3-pole (3PDT) Bifurcated With latching lever (S) Inductive load (cos ϕ = 0.4, L/R = 7 ms) 2 A at 220 VAC 2 A at 24 VDC Inductive load (cos ϕ = 0.
MY Characteristics Contact structure 2-pole (DPDT) Single Contact resistance*1 *2 50 mΩ max. Operate time*3 20 ms max. Release time*3 20 ms max. 3-pole (3PDT) Bifurcated Single 4-pole (4PDT) Single Bifurcated MY Number of poles (contact configuration) Crossbar bifurcated (CBG) 100 mΩ max. Maximum Mechanical 18,000 operations/h switching frequency Rated load 1,800 operations/h Insulation resistance*4 100 MΩ min.
MY Certified Standards ●UL certification (File No. E41515) MY Model MY2 MY2N MY2IN(S) MY2N-D2 MY2-D2 MY2IN-D2(S) MY2-CR MY2N-CR MYK MYQ·MYH Common Options (Order Separately) Common Precautions 12 Standard number UL508 Category NRNT2 Listed/ Recognized Recognition Operating Coil ratings 6 to 240 VAC 6 to 125 VDC No.
MY ●CSA certification (File No. LR31928) Standard number MY2Z MY2ZN MY2-02 MY2F MY2Z-D MY2Z-D2 MY2Z-CR MY2ZN-CR C22.2 NO.0, No.14 MY3 MY3N MY3-D MY3N-D2 MY3-02 MY3F C22.2 NO.0, No.14 MY4 MY4N MY4N(S) MY4-D MY4N-D2 MY4IN-D2(S) MY4-CR MY4N-CR MY4IN-CR(S) MY4Z MY4ZN MY4ZIN(S) MY4Z-D MY4ZN-D2 MY4ZIN-D2(S) MY4Z-C MY4ZN-CR MY4ZIN-CR(S) C22.2 No.14 MY4-02 MY4F MY4Z-02 MY4ZF C22.2 NO.0, No.14 6 to 240 VAC 6 to 125 VDC 6 to 240 VAC 6 to 125 VDC 3211 07 3211 07 No.
MY ●CE Marking Model MY MY2 MY2N MY2IN(S) MY2Z MY2ZN MY2-D MY2N-D2 MY2IN-D2(S) MY2-CR MY2N-CR MY2Z-CR MY2ZN-CR MY2Z-D MY2ZN-D2 MY2F EMC Directive Not applicable Low Voltage Directive Applicable Machinery Directive Not applicable Safety Category 1 MYK MY3 MY3N MY3-D MY3N-D2 MY3F MYQ·MYH MY4 MY4N MY4IN(S) MY4Z MY4ZN MY4ZIN(S) MY4-D MY4N-D2 MY4IN-D2(S) MY4Z-D MY4ZN-D2 MY4ZIN-D2(S) MY4-CR MY4N-CR MY4Z-CR MY4ZN-CR MY4F MY4ZF ●LR certification (Lloyd’s Register) Common Options (Order Separately) Commo
MY ●VDE certification Model Certification No.
MY Engineering Data (Reference Value) ●Maximum Switching Capacity 10 AC resistive load AC inductive load cos φ = 0.4 5 10 AC resistive load 5 1 DC resistive load 0.5 10 50 100 AC resistive load MYK 5 AC inductive load (cos φ = 0.4) 5 3 10 50 0.1 100 DC inductive load L/R = 7 ms 500 Contact voltage (V) 5 10 50 100 500 Contact voltage (V) MY4(S) and MY4Z(S) Contact current (A) AC resistive load 10 AC inductive load cos φ = 0.
MY 250 VAC resistive load 1,000 30 VDC resistive load 500 30 VDC resistive load 300 250 VAC resistive load 100 MY4(S) 10,000 5,000 3,000 250 VAC inductive load 1,000 30 VDC inductive load 500 30 VDC inductive load 300 250 VAC inductive load 100 1,000 300 30 VDC resistive load 100 30 30 10 4 6 8 10 0 1 2 3 4 30 VDC inductive load 1,000 30 VDC inductive load 500 300 250 VAC inductive load 100 5,000 3,000 250 VAC resistive load 1,000 500 300 30 VDC resistive load 100 30 VD
MY ●Ambient Temperature vs. Coil Temperature Rise MY2 DC Models 110 When rated voltage is applied 100 Operating temperature limit value (E-class insulation, 120°C) 90 80 Temperature rise (°C) MY Temperature rise (°C) MY2 AC Models, 50 Hz 120 70 60 110 When rated voltage is applied 100 Operating temperature limit value (E-class insulation, 120°C) 90 80 70 5 A contact current × 2 circuits 50 60 50 2.5 A contact current × 2 circuits 40 30 120 No contact current 20 10 10 10 20 2.
MY Models with built-in CR circuit for coil surge absorption MY@-CR With CR Without CR MY 282 V 2.5 msec ms 282 V 80 V 4.12 ms 9.4 ms 140 V 600 A C = 0.033 μF R = 6.8 kΩ 200 AC 200 AC A To digital memory scope A’ A’ Contact resistance (mΩ) Contact load: 5 VDC, 1 mA resistive load Malfunction level: Contact resistance of 100 Ω 30 28 MYK ●Contact Reliability Test MY4Z-CBG (Modified Allen Bradley Circuit) Number of Relays: 20 (average value) Malfunction rate: λ60 = 0.
MY Dimensions (Unit: mm) ●Plug-in terminals MY MY2, MY2N, MY2-D and MY2N-D2 MY2-CR, MY2N-CR Terminal Arrangement/ Internal Connection Diagram (Bottom View) MY2 (AC/DC Models) 2.6 Eight, 1.2-dia. × 2.2 oval holes 0.5 28 max. 36 max.* (Coil has no polarity) 6.4 21.5 max. MYK * For the MY2-CR 24 VAC and MY2N-CR 24 VAC, this dimension is 53 mm maximum.
MY MY3, MY3N, MY3-D, and MY3N-D2 2.6 MY Terminal Arrangement/ Internal Connection Diagram (Bottom View) MY3 (AC/DC Models) Eleven, 1.2-dia. × 2.2 oval holes 0.5 28 max. 6.3 0.5 36 max. 6.4 (Coil has no polarity) 21.5 max. MY3N MY3N-D2 AC Models (DC Models Only) (DC Models Only) (Coil has polarity) (Coil has no polarity) (Coil has polarity) (Coil has polarity) MYK MY3-D DC Models Note: 1. 2. 3. 4. An AC model has coil disconnection self-diagnosis.
MY MY4Z, MY4ZN, MY4Z-D, MY4ZN-D2 MY4Z-CR, MY4ZN-CR MY Terminal Arrangement/Internal Connection Diagram (Bottom View) MY4Z (AC/DC Models) 2.6 Fourteen, 1.2-dia. × 2.2 oval holes 0.5 28 max. 36 max. 6.4 (Coil has no polarity) 21.5 max.
MY MY(Z)IN(S) MY4(Z)IN-D2(S) MY4(Z)IN-CR(S) 2.6 MY 8 Fourteen, 1.2-dia. × 2.2 oval holes 6.3 0.5 28 max. 5 6.4 36 max. 8.05 14.2 21.5 max.
Miniature Power Latching Relays MYK MY Latching miniature power relays that retain contact operation status • A low power consumption type that retains contacts using a magnetic lock system. • Equipped with mechanical operation indicators to make operation status easy-to-see. Refer to Safety Precautions on pages 55 to 56 and Safety Precautions for All Relays. MYK Features Latching Relays MYK Retains contact operation status.
MYK Model Number Structure Model Number Legend (1) (2) (4) (3) (1) Basic model name MY - M Y (3) Type MY: Miniature Power Relays K: Latching relay (2) Number of poles/contacts 2: 2-pole, single (4) Options, terminal type None: Plug-in terminals 02: PCB terminals MYK Ordering Information When your order, specify the rated voltage.
MYK Ratings and Specifications Ratings ●Operating coil (AC) MY Set coil Rated voltage (V) Rated current (mA) 50 Hz AC DC 60 Hz Reset coil Coil resistance (Ω) Rated current (mA) 50 Hz 60 Hz Coil resistance (Ω) 12 57 56 72 39 38.2 130 24 27.4 26.4 320 18.6 18.1 550 100 7.1 6.9 5,400 3.5 3.4 3,000 12 110 110 50 235 24 52 470 25 940 48 27 1,800 16 3,000 Must Must Maximum operate release voltage (V) voltage (V) voltage (V) 80% max.* 80% max. 110% max.
MYK Maximum Switching Capacity Endurance Curve MY2K(-02) MYK(-02) MYK(-02) Number of operations (×104 operations) Number of operations (×104 operations) 10 AC resistive load 5 AC inductive load cos φ = 0.4 1 0.5 DC resistive load 500 110 VAC resistive load 220 VAC resistive load 100 50 DC inductive load L/R = 7 ms 10 10 50 500 110 VAC inductive load (cos φ = 0.4) 100 50 30 VDC resistive load 0.
MYK Dimensions (Unit: mm) ●Plug-in terminals Terminal Arrangement/ Internal Connection Diagram (Bottom View) MY2K MY 2.6 For AC For DC Note: R is a resistor for ampereturn correction. Built into models with specifications of 50 VAC or more. (The coil has no polarity.) Note: Pay close attention to the set coil and reset coil polarities. If the connections are not correct, unintended operation may occur. Ten, 1.2-dia. × 2.2 oval holes 0.5 28 max. 6.3 0.5 36 max. 21.5 max. 6.
Miniature Power Sealed Relays MYQ/MYH Refer to Safety Precautions on pages 55 to 56 and Safety Precautions for All Relays. MYK • Plastic sealed relays (MYQ) and hermetically sealed relays (MYH) that are resistant to effects from the surrounding environment • Highly airtight structures that are tough in environments where corrosive gases such as chloride gas, sulfuric gas, and silicone gas are generated. They are also resistant to environments where salt damage is occurred and where dust is generated.
MYQ·MYH Model Number Structure Model Number Legend - MY M Y (1) (2) (4) (3) (1) Basic model name (3) Type MY: Miniature Power Sealed Relays None: N: None With operation indicator* *Only MYQ (plastic sealed relay) (2) Contacts/seals Q4: Q4Z: 4H: 4ZH: 4-pole, single contacts, plastic sealed relays 4-pole, bifurcated contacts, plastic sealed relays 4-pole, single contacts, hermetically sealed relays 4-pole, bifurcated contacts, hermetically sealed relays MYK Ordering Information (4) Options,
MYQ·MYH Ratings and Specifications ●Operating coil (AC) Rated current (mA) AC 50 Hz 60 Hz Coil resistance (Ω) Coil inductance (H) Armature OFF Armature ON 24 53.8 46 180 0.69 1.3 100/110 11.7/12.9 10/11 3,750 14.54 24.6 110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1 200/220 6.2/6.8 5.3/5.8 12,950 54.75 91.07 220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4 12 75 165 0.734 1.37 24 36.9 650 3.2 5.72 48 18.5 2,600 10.6 21.0 100/110 9.1/10 11,000 45.6 86.
MYQ·MYH Characteristics Model MYQ MY Contact resistance*1 50 mΩ max. Operate time*2 20 ms max. Release time*2 Maximum switching frequency 20 ms max. Mechanical 18,000 operations/h Rated load 1,800 operations/h Insulation resistance*3 Dielectric strength MYK Vibration resistance Shock resistance MYH 100 MΩ min.
MYQ·MYH Engineering Data (Reference Value) Maximum Switching Capacity AC resistive load 3 AC inductive load cos φ = 0.4 1 0.7 0.5 AC contact load 5 AC inductive load cos φ = 0.4 1 0.3 0.5 DC resistive load DC contact load DC inductive load L/R = 7 ms 0.1 0.07 0.05 DC inductive load L/R = 7 ms 0.1 0.03 0.
MYQ·MYH Dimensions (Unit: mm) ●Plug-in terminals MY Plastic Sealed Relays MYQ4(Z)(N) MYQ4(Z)N DC Models AC Models (Coil has polarity) (Coil has no polarity) 2.6 21.5 max. Fourteen, 1.2-dia. × 2.2 oval holes 6.4 28 max. 28 max. 35.5 max. 21.5 max. MYK Note: 1. An AC model has coil disconnection self-diagnosis. 2. For the DC models, check the coil polarity when wiring and wire all connections correctly.
MY/MYK/MYQ·MYH Common Options (Order Separately) Ordering Information MY Front-mounting Sockets Number of pins Applicable relay model*1 Terminal Type Mounting Method Appearance Model Push-In Plus Terminal Mounted on a DIN track or (Integrated socket with release lever) with screws*2 PYF-08-PU MY2Z@-CR Push-In Plus Terminal (Without release lever) Mounted on a DIN track or with screws*2 PYF-08-PU-L MY2@ MY2IN(S) MY2Z@-CR Screwless terminal Mounted on a DIN track PYF08S MY2@ MY2IN(S) MY2Z@-C
MY/MYK/MYQ·MYH Number of pins Applicable relay model*1 Terminal Type Mounting Method Appearance Model MY MYK MY4@, MY4H MYQ4@, MY4@(S) MY2K Push-In Plus Terminal Mounted on a DIN track or (Integrated socket with release lever) with screws*2 PYF-14-PU MY4Z@-CBG-CR Push-In Plus Terminal (Without release lever) Mounted on a DIN track or with screws*2 PYF-14-PU-L MY4@, MY4H MYQ4@, MY4@(S) MY2K MY4Z@-CBG-CR Screwless terminal Mounted on a DIN track PYF14S MY4@, MY4H MYQ4@, MY4@(S) MY2K MY4Z@-C
MY/MYK/MYQ·MYH Back-mounting Sockets Number of pins Applicable relay model*1 Terminal Type Appearance Model Appearance PY08-Y1 Solder terminals PY08 MY2Z@-CR PY08-Y3 MY2@, MY2IN(S) PY08QN-Y1 Wrapping terminals Terminal length: 25 mm PY08QN MY2Z@-CR PY08QN-Y3 MY2@, MY2IN(S) PY08QN2-Y1 Wrapping terminals Terminal length: 20 mm MYK 8 MY MY2@, MY2IN(S) Models with Hold-down Clips*2 PY08QN2 MY2Z@-CR PY08QN2-Y3 MY3 Solder terminals PY11 PY11-Y1 MY3 Wrapping terminals Terminal length:
MY/MYK/MYQ·MYH Number of pins Applicable relay model*1 Terminal Type Appearance Model Appearance MY MY4@, MY4@(S), MY2K, MY4H, MYQ4@ PY14-Y1 Solder terminals PY14 MY4Z@-CBG-CR PY14-Y3 MY4@, MY4@(S), MY2K, MY4H, MYQ4@ PY14QN-Y1 Wrapping terminals Terminal length: 25 mm MYK 14 PY14QN MY4Z@-CBG-CR PY14QN-Y3 MY4@, MY4@(S), MY2K, MY4H, MYQ4@ PY14QN2-Y1 Wrapping terminals Terminal length: 20 mm PY14QN2 MY4Z@-CBG-CR MYQ·MYH MY4@, MY4@(S), MY4Z@-CBG-CR MY2K, MY4H, MYQ4@ PY14QN2-Y3 PCB term
MY/MYK/MYQ·MYH Hold-down Clip Appearance*1 Model*2 Weight*3 Approx. 0.54 g PYC-E1 Approx. 0.6 g MY PYC-A1 Application For connecting relays and sockets Approx. 1.4 g PYC-S Approx. 1.8 g Y92H-3 Approx. 0.7 g For connecting sockets, socket mounting plates, and relays PYC-1 Approx. 6 g MYQ·MYH For connecting models with built-in CR circuit for coil surge absorption (MY@-CR) and sockets MYK PYC-P *1. The appearance shown is one in which the relay, socket, and hold-down clip are assembled.
MY/MYK/MYQ·MYH Socket Accessories Hold-down Clip ●List of Hold-down Clip Models MY For Front-connecting Sockets Mounting method Terminal Type Push-In Plus Terminal 8 11 MYK 14 Screw terminal (M3.
MY/MYK/MYQ·MYH ●Front-connecting Socket Accessories Applicable sockets Pitch Application 7.75 mm Bridging contact terminals (common) Shape/external dimensions 3.90 L 12 18.5 2.25 PYF-08-PU(-L) PYF-14PU(-L) 1.57 Number L of poles (Length) Insulati on color 2 15.1 PYDN-7.75-020@ 3 22.85 PYDN-7.75-030@ 4 30.6 PYDN-7.75-040@ 20 154.6 Red (R) PYDN-7.75-200@ Blue (S) Yellow(Y) 8 224.35 PYDN-31.0-080@ 3.90 For Coil terminals 31.0 mm 18.
MY/MYK/MYQ·MYH For Screw Terminal Sockets (PYFZ-08/PYF08A/PYFZ-14/PYF14A) Short Bars MY Applicable sockets Pitch Application Number Insulation of poles color Shape/external dimensions Model*1 40° 22 2 PYD-025B@ (2P) (10 pcs./bag) 8 PYD-085B@ (8P) (10 pcs./bag) 3.3 5.6 PYFZ-08 PYF08A 22 mm 154 40° MYK 22 3.3 5.6 For bridging adjacent sockets B (Black) S (Blue) R (Red) 40° 29 2 PYD-026B@ (2P) (10 pcs./bag) 8 PYD-086B@ (8P) (10 pcs./bag) 2 PYD-020B@ (2P) (50 pcs./bag) 3.3 5.
MY/MYK/MYQ·MYH For Screw Terminal Sockets (PYFZ-08/PYFZ-14) Terminal covers Appearance Model PYFZ-08 PYCZ-C08 (2 pcs/set) PYFZ-14 PYCZ-C14 (1 pcs/set) MY Applicable sockets Dimensions with terminal cover (Unit: mm) MYK Note: These covers cannot be used for PYF08A and PYF14A. Use these covers in a combination with PYFZ-08 and PYFZ-14. PYCZ-C14 PYCZ-C08 72 max. 72 max. 34 max.
MY/MYK/MYQ·MYH Ratings and Specifications Characteristics Sockets MY Model Number Connection of pins PYF-08-PU PYF08S PYFZ-08 PYFZ-08-E PYF08A PYF08A-E Terminal Type Ambient operating temperature Ambient Continuous operating carry humidity current Push-In Plus Terminal −40 to 70°C Screwless terminal −55 to 70°C PYF08M PYF11A MYK PYF-14-PU PYF14S PYFZ-14 PYFZ-14-E PYF14A PYF14A-E PYF14T PY08 PY08-Y1 PY08-Y3 PY08QN PY08QN-Y1 PY08QN-Y3 PY08QN2 PY08QN2-Y1 PY08QN2-Y3 PY08-02 PY11 PY11-Y1 PY11QN PY11
MY/MYK/MYQ·MYH Socket Accessories ●For Front-connecting Sockets Short Bars Applicable sockets PYF-08-PU(-L) PYF-14-PU(-L) Bridging contact terminals (common) PYFZ-08 PYF08A PYFZ-14 PYF14A PYDN-7.75-020@ PYDN-7.75-030@ PYDN-7.75-040@ PYDN-7.
MY/MYK/MYQ·MYH Dimensions (Unit: mm) Height with Socket ●Front-connecting Sockets MY • Push-In Plus Terminal (PYF-@-PU) MY 67.5 63.1 28.1 (3.9) PYF-@@-PU MYK • Screwless terminal (PYF08S, PYF14S) MY MY 73.6 72.6 64 28.6 64 28.6 (3.4) PYF08S (3.4) PYF14S MYQ·MYH • Screw terminal (PYFZ-@(-E), PYF@A(-E), PYF14T, PYF08M) MY 70 (87) 66 (83) MY 54 (71) PYFZ-@(-E) PYF@A(-E) PYF14T PYF08M Common Options (Order Separately) Note: 1. The PYF@A can be mounted on a track or with screws. 2.
MY/MYK/MYQ·MYH Front-connecting Sockets ●Push-In Plus Terminal MY PYF-08-PU(-L) 71.5 Terminal Arrangement/Internal Connection Diagram Mounting Hole Dimensions (Top View) 67.5 A1 (13) 30.8 A2 (14) Two, M3 screw hole or two, 3.5-dia. holes 108 28.1 (4.2) 25.6 14 (5) 44 (8) 11 (9) 41 (12) Note: Pull out the hooks to mount the Socket with screws. Note: The numbers in parentheses are traditionally used terminal numbers. 27.35 3.9 42 (4) MYK 90 Release lever* 35.3 12 (1) 25.6 31 34.
MY/MYK/MYQ·MYH ●Screwless terminal PYF08S 38.2 max. Terminal Arrangement/Internal Connection Diagram MY 36.5 max. 32.6 23.2 max. 27.6 22.6 12 9 (41) (11) 8 5 (44) (14) 4 1 (3.4) (12) (42) --- 24.5 (A1) (A2) 85 max. 35.4 14 13 (Top View) MYK 28.6 (5) (5.3) Note: The number shown in parentheses is the DIN standard. 32.6 PYF14S Terminal Arrangement/Internal Connection Diagram 36.5 max. 12 11 10 9 (41) (31) (21) (11) 8 MYQ·MYH 31 max. 22.
MY/MYK/MYQ·MYH Front-connecting Sockets ●Screw terminal MY PYFZ-08 6+0.2 –0.1 Two, 4.2 × 5 mounting holes 8-M3 × 8 35.4 72 max. 4 6 23 max. 30 max. MYK PYFZ-08-E (Finger-protection structure) 6+0.2 –0.1 Two, 4.2 × 5 mounting holes 8-M3 × 8 72 max. 35.4 Terminal Arrangement/ Internal Connection Diagram Mounting Hole Dimensions Two, M3, M4, or 4.5-dia. holes 4 4 1 5 31 max. 59±0.3 PYF08A Two, 4.2 × 5 mounting holes 6+0.2 –0.1 12 9 14 13 3.4 8-M3 × 8 (Top View) 15±0.
MY/MYK/MYQ·MYH PYF08M 8-M3.5 × 7.5 Terminal Arrangement/Internal Connection Diagram 3 dia. 7± 0.2 MY 33.5 max. 1.5 44.5 max. 3.5-dia. mounting hole 6.5-dia. countersinking depth 11.5 PYF11A Two, 4.2 × 5 mounting holes 18 max. 6+0.2 –0.1 4 8 12 1 5 9 14 13 Mounting Hole Dimensions 3.5-dia. hole 20±0.1 3.5-dia. hole or M3 screw hole (Top View) Terminal Arrangement/Internal Connection Diagram 3.4 Mounting Hole Dimensions Two, M3, M4, or 4.5-dia. holes 11-M3 × 8 3 2 1 6 5 4 59±0.
MY/MYK/MYQ·MYH PYF14A Two, 4.2 × 5 mounting holes 6+0.2 –0.1 3.4 14-M3 × 8 MY 35.4 72 max. Mounting Hole Dimensions Two, M3, M4, or 4.5-dia. holes 4 6 29.5 max. 16.5 30 max. PYF14A-E (Finger-protection structure) Two, 4.2 × 5 mounting holes 6+0.2 –0.1 59±0.3 Terminal Arrangement/Internal Connection Diagram 3.4 14-M3 × 8 8 7 6 5 35.4 72 max. (Top View) Note: Track mounting is also possible. MYK 22±0.2 3 2 1 12 11 10 9 4 14 13 4 4 6 29.5 max. (Top View) 16.5 31 max.
MY/MYK/MYQ·MYH Back-connecting Socket ●Solder terminals MY PY08 * Terminal Arrangement/Internal Connection Diagram Eight, 3 × 1.2 oval holes 25.5 max. 29.5 max. 5 2.7 2.6 7.7 24 max. 20 max. L MYK 6 2.6 7 8 9 24 max. 10 25.8±0.2 21.4 +0.2 0 Mounting Hole Dimensions 25.8±0.2 21.4 +0.2 0 11 (Bottom View) Terminal Arrangement/Internal Connection Diagram 25.5 max. 29.5 max. 5 2.6 7.7 2.7 20 max. Mounting Hole Dimensions 1 2 3 4 5 6 7 8 25.8±0.2 9 10 11 12 24 max.
MY/MYK/MYQ·MYH ●PCB terminals PY08-02 Terminal Arrangement/Internal Connection Diagram 1.0 25.5 max. 29.5 max. 2.7 4.3 2 22 max. 16.5 max. 1 4 5 8 9 12 13 14 13.2 5.8 4.1 6.35 0.3 25.5 max. 29.5 max. 4.3 Mounting Hole and PCB Dimensions 2 22 max. 16.5 max. 2 3 4 5 6 7 8 9 10 13.2 5.8 4.1 6.35 6.4 11 (Bottom View) PY14-02 Eleven, 1.3-dia. holes 4.2 Mounting Hole and PCB Dimensions Terminal Arrangement/Internal Connection Diagram 1.0 12.65 MYK 2.7 1 Eight, 1.
MY/MYK/MYQ·MYH ●Accessories for DIN Track Mounting MY DIN Tracks PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 25 1,000 (500)* End Plate PFP-M 10 25 15 (5)* 10 6.2 1.8 1 50 35.5 35.3 1.8 MYK 11.5 10 1.3 4.8 M4 spring washer 16 12 5 34.8 44.3 MYQ·MYH Common Options (Order Separately) Common Precautions 54 1 *Dimensions in parentheses are for PFP-50N. M4 × 8 pan head screw Spacer PFP-S 27±0.15 16.
MY/MYK/MYQ·MYH Safety Precautions Relays MY Be sure to read the Safety Precautions for All Relays in the website at the following URL: http://www.ia.omron.com/product/cautions/36/safety_precautions.html ●Relay Replacement Warning Indications WARNING Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.
MY/MYK/MYQ·MYH ●Latching Relays (MYK) • For applications that use a 200 VAC power supply, connect external resistors Rs and Rr to a 100 VAC Relay. MY 1 4 5 8 9 10 11 12 ●Hermetically Sealed Relays (MYH/MYQ) Relays with PCB Terminals When a Relay with PCB Terminals is mounted, a short-circuit can occur depending on the design of the PCB pattern because the Relay itself is made out of metal.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com © OMRON Corporation 2018-2019 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_10_4_0719 Cat. No.