Datasheet

LY
11
When ordering a model that is certified for VDE or Lloyd’s Register (LR) standards, always specify “VDE-certified Model” or “LR Standard-
certified Model” with your order.
VDE Certification (Certificate No. 6359, EN 61810-1)
LR-certified Models (File No. 00/10047)
Compliance with Electrical Appliances and Material Safety Act
All standard models comply with the Electrical Appliances and Material Safety Act.
Model Coil ratings
Number of
poles
Contact ratings
Certified number
of operations
LY
@
-VD
6, 12, 24, 50,
110, or 220 VAC
6, 12, 24, 48,
or 110 VDC
1
10 A, 220 VAC resistive load
200,000
operations
7 A, 220 VAC inductive load
10 A, 28 VDC resistive load
7 A, 28 VDC inductive load
2
7 A, 220 VAC resistive load
4 A, 220 VAC inductive load
7 A, 28 VDC resistive load
4 A, 28 VDC inductive load
Model Coil ratings
Number of
poles
Contact ratings
LY
@
6 to 240 VAC
6 to 110 VDC
2 7.5 A, 230 VAC inductive load
4 5 A, 24 VDC inductive load
Model Coil ratings
Number of
poles
Contact ratings
LY
@
6 to 240 VAC
6 to 120 VDC
1 15 A at 200 VAC
2
3
4
10A at 200 VAC