Datasheet
LY
10
Details on Safety-standard-certified Models, LY@
• Standard models are certified for the UL, CSA, and SEV safety standards.
• Refer to Model Number Structure on page 1 for a list of applicable models.
• The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use.
UL-certified Models (File No. E41643)
TÜV-certified Models (File No. R50030064,
EN 61810-1)
CSA-certified Models (File No. LR31928)
SEV-certified Models (File No. 11, 0573)
Model Coil ratings
Number of
poles
Contact ratings
Certified number
of operations
LY
6 to 240VAC
6 to 125VDC
1
15A, 120VAC (General use)
100,000 operations
15A, 240VAC (General use)
6,000 operations
15A, 30VDC (Resistive)
1/2HP, 120VAC
100,000 operations
8.5FLA, 30LRA, 120VAC
TV-5, 120VAC 25,000 operations
470VA, Pilot duty, 120VAC 6,000 operations
6 to 240VAC
6 to 125VDC
2
15A, 120VAC (General use)
100,000 operations
12A, 240VAC (General use)
6,000 operations
7A, 250VAC (General use)
15A, 30VDC (Resistive)
5A, 38VDC (Resistive)
1/2HP, 120VAC
100,000 operations
1/3HP, 240VAC 1,000 operations
8.5FLA, 30LRA, 120VAC
100,000 operations
5FLA, 50LRA, 50VDC
TV-3, 120VAC 25,000 operations
345VA, Pilot duty, 120-240VAC
6,000 operations
B300/R300
6 to 240VAC
6 to 125VDC
3
4
10A, 240VAC (General use)
(Same polarity)
6,000 operations
10A, 30VDC (General use)
(Same polarity)
2A, 40VDC (Resistive)
(Same polarity)
1/2HP, 240VAC 1,000 operations
0.6A, 100VDC (Resistive)
(Same polarity)
6,000 operations
Model Coil ratings
Number of
poles
Contact ratings
Certified number
of operations
LY
@
6 to 240 VAC
6 to 110 VDC
1
15 A, 110 VDC resistive load
200,000
operations
10 A, 110 VAC inductive load
10 A, 250 VAC resistive load
7A, 250 VAC inductive load
10 A, 30 VDC resistive load
7 A, 30 VDC inductive load
2
10 A, 110 VAC resistive load
7.5A, 110 VAC inductive load
7A, 250 VAC resistive load
4 A, 250 VAC inductive load
7 A, 30 VDC resistive load
4 A, 30 VDC inductive load
3
4
10 A, 110 VAC resistive load
100,000
operations
7.5A, 110 VAC inductive load
Model Coil ratings
Number of
poles
Contact ratings
Certified number
of operations
LY
6 to 240VAC
6 to 125VDC
1
15A, 120VAC (General use)
100,000 operations
15A, 240VAC (General use)
6,000 operations
15A, 30VDC (Resistive)
1/2HP, 120VAC
100,000 operations
8.5FLA, 30LRA, 120VAC
TV-5, 120VAC 25,000 operations
470VA, Pilot duty, 120VAC 6,000 operations
6 to 240VAC
6 to 125VDC
2
15A, 120VAC (General use)
6,000 operations
12A, 240VAC (General use)
7A, 250VAC (General use)
15A, 30VDC (Resistive)
5A, 38VDC (Resistive)
1/2HP, 120VAC
100,000 operations
1/3HP, 240VAC 1,000 operations
8.5FLA, 30LRA, 120VAC
100,000 operations
5FLA, 50LRA, 50VDC
TV-3, 120VAC 25,000 operations
345VA, Pilot duty, 120-240VAC
6,000 operations
B300/R300 Pilot duty
6 to 240VAC
6 to 125VDC
3
4
10A, 240VAC (General use)
(Same polarity)
6,000 operations
10A, 30VDC (Resistive)
(Same polarity)
1/8HP, 240VAC (Same polarity)
1,000 operations1/2HP, 240VAC (Same polarity)
1/3HP, 240VAC (Same polarity)
2A, 40VDC (Resistive)
6,000 operations
0.6A, 100VDC (Resistive)
Model Coil ratings
Number of
poles
Contact ratings
Certified number
of operations
LY
@
6 to 110 VDC
2 to 240 VAC
1
15 A at 24 VDC
6,000 operations
15 A at 220 VAC
6 to 110 VDC
2 to 240 VAC
2 to 4
10 A at 24 VDC
10 A at 220 VAC