Datasheet

MY
8
Miniature Power Relays: MY4
Ordering Information
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products with voltages other than the above coil
specifications.
3. The above models and specifications are new versions in the MY Series.
4. Except for MY4(N)-CR Relays with the above voltage specifications, all Relays have a height of 53 mm or less.
If Mounting Brackets are required, refer to page 33 for selection information.
Ratings and Specifications
Ratings
Operating Coil (Standard Models)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/20% for the AC rated current and ±15% for the
DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
specified value.
Contact Ratings
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.
Classification Model
Rated voltage (V)
Standard products Made-to-order items
Standard models MY4
24, 100/110, or 200/220 VAC 12, 110/120, or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in operation indicators MY4N
12, 24, 100/110, 110/120, 200/220, or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in diodes MY4-D 12, 24, 48, or 100/110 VDC
Models with built-in diodes and operation
indicators
MY4N-D2 12, 24, or 100/110 VDC 48 VDC
Models with built-in CR circuits MY4-CR 100/110 or 200/220 VAC 110/120 or 220/240 VAC
Models with built-in CR circuits and operation
indicators
MY4N-CR 100/110, 110/120, or 200/220 VAC 220/240 VAC
Refer to the standards certifications and compliance
section of your OMRON website for the latest
information on certified models.
Whenyourorder,specifytheratedvoltage.
Item Rated current (mA)
Coil resistance
(Ω)
Coil inductance (H)
Must-
operate
voltage (V)
Must-
release
voltage (V)
Maximum
voltage (V)
Power consumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz
Armature
OFF
Armature
ON
AC
12 106.5 91 46 0.17 0.33
80% max.
*1
30% min.
*2
110% of rated
voltage
Approx. 0.9 to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110
11.7/12.9 10/11 3,750 14.54 24.6
110/120
9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220
6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240
4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC
12 72.7 165 0.73 1.37
10% min.
*2
Approx. 0.9
24 36.3 662 3.2 5.72
48 17.6 2,725 10.6 21.0
100/110
8.7/9.6 11,440 45.6 86.2
Load
Item
Resistive load
Inductive load
(cos φ = 0.4, L/R = 7 ms)
Rated load
3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current 3 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 3 A
Contact configuration 4PDT
Contact structure Single
Contact materials Au cladding + Ag alloy
Type
Item
Standard
models
Model with built-in operation
indicator, diode, or CR circuit
Ambient
operating
temperature
*1
55 to 70° C 55 to 60° C
*2
Ambient
operating
humidity
5% to 85%