Datasheet

33
MY
Options (Order Separately)
Connection Socket and Mounting Bracket Selection Table
(The possible combinations of models with plug-in terminals and sockets)
Note: Refer to Common Socket and DIN Track Products for the external dimensions of the Socket Relays and details on Hold-down Clips.
*1. The information in parentheses is the model number of the applicable Mounting Bracket. Mounting Brackets are sold in sets of two. However, the PYC-P is just
one Mounting Bracket.
*2. The PYF@A-E has a terminal cover with finger protection. The Socket and Terminal Cover are integrated into one unit. Round terminals cannot be used.
Use forked terminals or ferrules instead.
*3. A Push-In Plus Terminal Block Socket functions as a release lever to hold or remove a Relay. Refer to PYF-
@@
-PU/P2RF-
@@
-PU for details.
*4. If an MY@I(S) Relay with a Latching Lever is used in combination with a PY@-02 Socket for Relays with PCB Terminal Socket and PYC-P Mounting Brackets, the
lever will not operate.
*5. We recommends using the PYC-E1 Mounting Bracket for a MY2I(S) Relay with Latching Lever. (If the PYC-A1 is used with the MY2I(S), the latching lever will be
blocked by the Mounting Bracket and the lever will not operate.)
*6. The Mounting Brackets are applicable for Relays with a height of 36 mm or less. If the Relay height is greater than 53 mm, use Y92H-3 for the Front-mounting
Socket and PYC-1 for the Back-mounting Socket. (The Y92H-3 is a set of two Brackets and the PYC-1 is just one Bracket.)
Mounting Heights with Sockets (Unit: mm)
Connecting
method
Front-mounting Sockets (PYF
@
)
Back-mounting Sockets (PY
@
)
Mounting
method
Track or screw mounting
Screw
mounting
only
Track or
screw
mounting
Screw terminals
Push-In Plus
Terminal
Block *3
Solder terminals
Wrapping terminals
Relays with
PCB
Terminals
*4
Terminal Type
Screw
terminal
size: M3
Screw terminal
size: M3
(finger
protection
structure) *2
Screw terminal size:
M3.5
Terminal length:
25 mm
Terminal length:
20 mm
Number
of pins
(Sold separately: Hold-down Clips) *1
With
Release
Lever
Without
Mounting
Brackets *1
With
Mounting
Brackets
Without
Mounting
Brackets *1
With
Mounting
Brackets
Without
Mounting
Brackets *1
With
Mounting
Brackets
(Sold
separately:
Hold-down
Clips)
*1
8
MY2
@ (except
for MY2K@ and
MY2Z@-CR)
PYF08A
(PYC-A1)
PYF08A-E
(PYC-A1)
---
PYF08M
(PYC-P)
PYF-08-PU
PY08
(PYC-P)
PY08-Y1
PY08QN
(PYC-P)
PY08QN-Y1
PY08QN2
(PYC-P)
PY08QN2-Y1
PY08-02
(PYC-P)
MY2I(S) *5
PYF08A
(PYC-E1)
PYF08A-E
(PYC-E1)
MY2Z
@
-CR *6
PYF08A
(Y92H-3)
PYF08A-E
(Y92H-3)
---
PY08
(PYC-1)
PY08-Y3
PY08QN
(PYC-1)
---
PY08QN2
(PYC-1)
---
PY08-02
(PYC-1)
11 MY3
@
PYF11A
(PYC-A1)
--- --- --- ---
PY11
(PYC-P)
PY11-Y1
PY11QN
(PYC-P)
PY11QN-Y1
PY11QN2
(PYC-P)
PY11QN2-Y1
PY11-02
(PYC-P)
14
MY4
@
MY4H
MYQ4
MY4(S)
MY2K
PYF14A
(PYC-A1)
PYF14A-E
(PYC-A1)
PYF14T
(PYC-A1)
--- PYF-14-PU
PY14
(PYC-P)
PY14-Y1
PY14QN
(PYC-P)
PY14QN-Y1
PY14QN2
(PYC-P)
PY14QN2-Y1
PY14-02
(PYC-P)
Front-mounting Sockets
Screw terminal
(PYF
@
A (-E), PYF14T, PYF08M)
Push-In Plus Terminal Block Sockets
(PYF-
@
-PU)
Back-mounting Sockets
Solder terminals/Wrapping terminals
(PY
@
)
Relays with PCB Terminals
(PY
@
-02)
MY
MY
PYF@A or PYF14T PYF08M
54 (71)
66 (83)70 (87)
Note: 1.
The PYF
@
A can be mounted on a track or with screws.
2.
The heights given in parentheses are the measurements
for 53-mm-high Relays.
3.
Use the PYC-P Mounting Bracket for the PYF08M.
3.9
28.1
67.5
64.1
MY
PYF-@-PU
39 (56)
MY
PY@
MY
48.2
PY@-02