Datasheet

25
MY
Miniature Power Relays: MY4Z-CBG
Ordering Information
Note: Ask your OMRON representative for details on the time required to deliver made-to-order products.
Ratings and Specifications
Ratings
Operating Coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/20% for the AC rated current and ±15% for the
DC coil resistance.
2. The AC coil resistance and inductance values are reference values only
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
specified value.
Contact Ratings
Characteristics
Note:
The above values are initial values.
*1.
Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2.
Measurement conditions: With rated operating power applied, not including contact bounce.
Ambient temperature condition: 23° C
*3.
Measurement conditions: For 500 VDC applied to the same location as for dielectric strength
measurement.
*4.
Ambient temperature condition: 23° C
*5.
This value was measured at a switching frequency of 120 operations per minute.
Classification Model
Rated voltage (V)
Standard products Made-to-order items
Standard models MY4Z-CBG
100/110 or 200/220 VAC 110/120 VAC
24 or 100/110 VDC 12 or 48 VDC
Models with built-in
operation indicators
MY4ZN-CBG
--- 100/110 or 200/220 VAC
--- 24 VDC
Whenyourorder,specifytheratedvoltage.
Item Rated current (mA)
Coil
resistance (Ω)
Coil inductance (H)
Must-operate
voltage (V)
Must-release
voltage (V)
Maximum
voltage (V)
Power consumption
(VA, W)
Rated voltage (V) 50 Hz 60 Hz Armature OFF Armature ON
AC
100/110
11.7/12.9 10/11 3,750 14.54 24.6
80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9 to 1.3
(at 60 Hz)
110/120
9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220
6.2/6.8 5.3/5.8 12,950 54.75 94.07
DC
12 75 160 0.73 1.37
10% min.
*2
Approx. 0.924 36.9 650 3.2 5.72
100/110
9.1/10 11,000 45.60 86.20
Load
Item
Resistive load
Inductive load
(cos φ = 0.4, L/R = 7 ms)
Rated load
1 A at 220 VAC
1 A at 24 VDC
0.3 A at 220 VAC
0.5 A at 24 VDC
Rated carry
current
1 A
Maximum contact
voltage
250 VAC, 125 VDC
Maximum contact
current
1 A 1 A
Contact structure Crossbar bifurcated
Contact materials Au cladding + AgPd
Contact resistance
*1
100 mΩ max.
Operation time
*2
20 ms max.
Release time
*2
20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Electrical 1,800 operations/h
Insulation resistance
*3
100 MΩ
Dielectric
strength
Between coil
and contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts
of different polarity
Between contacts
of the same polarity
700 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.5-mm single amplitude
(1.0-mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.5-mm single amplitude
(1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 200 m/s
2
Endurance
Mechanical
5,000,000 operations min. (operating
frequency: 18,000 operations/hr)
Electrical
*4
50,000 operations min. (switching
frequency: 1,800 operations/h) at rated load
Failure rate P value (reference value)
*
5
100 µA at 1 VDC
Ambient operating temperature
25 to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 35 g