Datasheet
21
MY
Ambient Temperature vs.
Must-operate and Must-release Voltage
Ambient Temperature vs. Coil Temperature Rise
MY2 AC Models MY2 AC Models, 50 Hz MY2 DC Models
MY2 DC Models MY4 AC Models, 50 Hz MY4 DC Models
MY4 AC Models
MY4 DC Models
Models with built-in diodes
The diode absorbs surge from the coil. This type is best suited for applications with semiconductor circuits.
With Diode
Without Diode
Note: 1. Make sure that the polarity is correct.
2. The release time will increase, but the 20-ms specification for standard models is satisfied.
3. Diode properties:The diode has a reversed dielectric strength of 1,000 V.
Forward current: 1 A
Models with Built-in CR Circuits
With CR Without CR
100
80
60
40
20
0
−60 −30 0 30 60 90
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
120
100
110
80
90
70
60
50
40
10
20
30
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
Temperature rise (°C)
When rated voltage is applied
5 A contact current × 2 circuits
2.5 A contact current × 2 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
120
100
110
80
90
70
60
50
40
10
20
30
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
Temperature rise (°C)
When rated voltage is applied
5 A contact current × 2 circuits
2.5 A contact current × 2 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
−60 −30 0 30 60 90
100
80
60
40
20
0
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
10 20 30 40 50 60 70 80
Ambient temperature (°C)
When rated voltage is applied
3 A contact current × 4 circuits
1.5 A contact current × 4 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
120
100
110
80
90
70
60
50
40
10
20
30
0
Temperature rise (°C)
120
100
110
80
90
70
60
50
40
10
20
30
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
Temperature rise (°C)
When rated voltage is applied
3 A contact current × 4 circuits
No contact current
Operating temperature limit value
(E-class insulation, 120° C)
1.5 A contact current × 4 circuits
−60 −30 0 30 60 90
80
60
40
20
0
100
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
−60 −30 0 30 60 90
100
80
60
40
20
0
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Must-operate voltage
Must-release voltage
Number of Relays: 10
(average value)
OFFON
A
A’
Di
To digital
memory
24 VDC
OFFON
A
A’
To digital
memory
24 VDC
140 V
A
A’
C = 0.033 μF
R = 6.8 kΩ
282 V
80 V
4.12 ms
9.4 ms
200 AC
A
A’
A
A’
To digital
memory
scope
msec
2.5
600 V
282 V
ms
2.5
200 AC