Datasheet
MY
20
Engineering Data MY2, MY3, MY4, MY4Z, MY@-02, and MY@F
Engineering Data
Maximum Switching Capacity
MY2 and MY3
Endurance Curve
MY2 and MY3 MY2 and MY3
MY4 and MY4Z MY4 MY4
MY4Z MY4Z
DC inductive load
(L/R = 7 ms)
DC resistive load
AC resistive load
AC inductive load
(cos φ = 0.4)
10
0.1
0.5
1
5
5 10 50 100 500
Contact voltage (V)
Contact current (A)
10
50
100
500
012345 67
24 VDC resistive load
110 VAC resistive load
220 VAC resistive load
10
50
100
500
012345 67
Contact current (A)
Number of operations (×10
4
operations)
10
50
100
500
01 2 3
10
50
100
500
01 2 3
24 VDC inductive load
(L/R = 7 ms)
110 VAC inductive load
(cos φ = 0.4)
10
50
100
500
01 2 3
Contact current (A)
Number of operations (×10
4
operations)
220 VAC inductive load
(cos φ = 0.4)
Contact current (A)
AC inductive load
(cos φ = 0.4)
10
0.1
0.5
1
5
5 10 50 100 500
Contact voltage (V)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC resistive load
30 VDC
resistive load
110 VAC resistive load
220 VAC resistive load
10
50
100
500
0123
Contact current (A)
Number of operations (×10
4
operations)
10
50
100
500
0 0.5 1.5
30 VDC inductive load
(L/R = 7 ms)
110 VAC inductive load (cos φ = 0.4)
220 VAC inductive load
(cos φ = 0.4)
10
50
100
500
0 1.0 1.5
Contact current (A)
Number of operations (×10
4
operations)
24 VDC resistive load
220 VAC resistive load
10
50
100
500
01 2 3
Contact current (A)
Number of operations (×10
4
operations)
24 VDC inductive load (L/R = 7 ms)
10
50
100
500
0 0.5 1.5
110 VAC inductive load (cos φ = 0.4)
220 VAC inductive load (cos φ = 0.4)
10
50
100
500
0 0.5
1.0
1.5
Contact current (A)
Number of operations (×10
4
operations)