Datasheet

MY
8
MY
MYQ
·
MYH
MYK
Common Options (Order Separately)
Common Precautions
Ratings and Specifications
Ratings
Operating Coils
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for AC rated current and ±15% for DC coil
resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% maximum.
To ensure operation, apply at least 80% of the rated value (at a coil temperature of 23
°C).
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
specified value.
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for AC rated current and ±15% for DC coil
resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% maximum.
To ensure operation, apply at least 80% of the rated value.
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
Terminal Type Classification
Number
of poles
Contacts Without operation indicator With operation indicator
Plug-in terminals
Standard models
2 Single MY2 MY2N
4
Single MY4 MY4N
Bifurcated MY4Z MY4ZN
Models with built-in diode for
coil surge absorption
(DC coil specification only)
2 Single MY2-D MY2N-D2
4
Single MY4-D MY4N-D2
Bifurcated MY4Z-D MY4ZN-D2
Models with built-in CR circuit
for coil surge absorption
(AC coil specification only)
2 Single MY2-CR MY2N-CR
4
Single MY4-CR MY4N-CR
Bifurcated MY4Z-CR MY4ZN-CR
Item Rated current (mA)
Coil resistance
(Ω)
Coil inductance (H) Must
operate
voltage (V)
Must
release
voltage (V)
Maximum
voltage (V)
Power
consumption
(VA, W)
Rated voltage (V) 50 Hz 60 Hz Armature OFF Armature ON
AC
12 106.5 91 46 0.17 0.33
80% max.*1
30% min.*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC
12 72.7 165 0.73 1.37
10% min.*2 Approx. 0.9
24 36.3 662 3.2 5.72
48 17.6 2,725 10.6 21.0
100/110 8.7/9.6 11,440 45.6 86.2
Terminal Type Classification
Number
of poles
Contacts Without operation indicator With operation indicator
Plug-in terminals
Standard models 2 Bifurcated MY2Z MY2ZN
Models with built-in diode for
coil surge absorption
(DC coil specification only)
2 Bifurcated MY2Z-D MY2ZN-D2
3 Single MY3-D MY3N-D2
Models with built-in CR circuit
for coil surge absorption
(AC coil specification only)
2 Bifurcated MY2Z-CR MY2ZN-CR
Item Rated current (mA)
Coil resistance
(Ω)
Coil inductance (H) Must
operate
voltage (V)
Must
release
voltage (V)
Maximum
voltage (V)
Power
consumption
(VA, W)
Rated voltage (V) 50 Hz 60 Hz Armature OFF Armature ON
AC
12 106.5 91 46 0.17 0.33
80% max.*1
30% min.*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC
12 75 160 0.73 1.37
10% min.*2 Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2