Datasheet
MY
13
MY
MYQ
·
MYH
MYK
Common Options (Order Separately)
Common Precautions
●CSA certification (File No. LR31928)
●TÜV Rheinland certification (Certification No. R50030059)
Model Standard number
Class
number
Operating Coil
ratings
No. of poles Contact ratings
Certified
number of
operations
MY2
MY2N
MY2IN(S)
MY2N-D2
MY2-D2
MY2IN-D2(S)
MY2-CR
MY2N-CR
C22.2 NO.0, No.14 6 to 240 VAC
6 to 125 VDC
2 7 A, 240 VAC (Resistive)
7 A, 24 VDC (Resistive)
5 A, 240 VAC (General Use)
5 A, 250 VAC (Resistive)
5 A, 30 VDC (Resistive)
6,000
1/6 HP, 250 VAC (Same polarity)
1/10 HP, 120 VAC (Same polarity)
1,000
MY2Z
MY2ZN
MY2-02
MY2F
MY2Z-D
MY2Z-D2
MY2Z-CR
MY2ZN-CR
C22.2 NO.0, No.14 6 to 240 VAC
6 to 125 VDC
2 7 A, 240 VAC (General Use) (Same polarity)
7 A, 24 VDC (Resistive) (Same polarity)
5 A, 240 VAC (General Use) (Same polarity)
5 A, 30 VDC (Resistive)
5 A, 250 VAC (Resistive) (Same polarity)
0.2 A, 120 VDC (Resistive)
6,000
1/6 HP, 250 VAC
1/10 HP, 120 VAC
1,000
MY3
MY3N
MY3-D
MY3N-D2
MY3-02
MY3F
C22.2 NO.0, No.14 6 to 240 VAC
6 to 125 VDC
3 5 A, 28 VDC (Resistive)
5 A, 240 VAC (General Use)
7 A, 240 VAC (General Use)
7 A, 24 VDC (Resistive)
6,000
1/6 HP, 250 VAC 1,000
MY4
MY4N
MY4N(S)
MY4-D
MY4N-D2
MY4IN-D2(S)
MY4-CR
MY4N-CR
MY4IN-CR(S)
MY4Z
MY4ZN
MY4ZIN(S)
MY4Z-D
MY4ZN-D2
MY4ZIN-D2(S)
MY4Z-C
MY4ZN-CR
MY4ZIN-CR(S)
C22.2 No.14 3211 07 6 to 240 VAC
6 to 125 VDC
4 5 A, 240 VAC (General Use) (Same polarity)
5 A, 28 VDC (General Use) (Same polarity)
5 A, 250 VAC (Resistive) (Same polarity)
5 A, 30 VDC (Resistive) (Same polarity)
0.2 A, 120 VDC (Resistive) (Same polarity)
6,000
1/6 HP, 250 VAC (Same polarity)
1/10 HP, 120 VAC (Same polarity)
1,000
B300 Pilot Duty (Same polarity) 6,000
MY4-02
MY4F
MY4Z-02
MY4ZF
C22.2 NO.0, No.14 3211 07 6 to 240 VAC
6 to 125 VDC
4 7 A, 240 VAC (General Use) (Same polarity)
7 A, 24 VDC (Resistive) (Same polarity)
5 A, 240 VAC (General Use) (Same polarity)
5 A, 30 VDC (Resistive)
5 A, 250 VAC (Resistive) (Same polarity)
0.2 A, 120 VDC (Resistive)
6,000
1/6 HP, 250 VAC
1/10 HP, 120 VAC
1,000
Model Operating Coil ratings Contact ratings Certified number of operations
MY2Z
MY2ZN
MY2-02
MY2F
MY2Z-D
MY2Z-D2
MY2Z-CR
MY2ZN-CR
6 to 125 VDC,
6 to 240 VAC
5 A, 250 VAC (cos ϕ = 1.0) 100,000
MY3
MY3N
MY3-D
MY3N-D2
MY3-02
MY3F
5 A, 250 VAC (cos ϕ = 1.0)
0.8 A, 250 VAC (cos ϕ = 0.4)
MY4-02
MY4F
MY4Z-02
MY4ZF
3 A, 120 VAC (cos ϕ = 1.0)
0.8 A, 250 VAC (cos ϕ = 0.4)