Datasheet
Cable Access Options
To tailor the OS32C to your installation, two options are
available for the location of the power and ethernet
connections:
OS32C-BP(-4M)/OS32C-BP-DM(-4M) (Cable access from
the back)
OS32C-SP1(-4M)/OS32C-SP1-DM(-4M) (Cable
access from the left side)
These can be selected according to
the needs of AGV or facilities design.
OS32C with cable access
from the back
(OS32C-BP(-4M)/
OS32C-BP-DM(-4M))
OS32C with cable access
from the left side
(OS32C-SP1(-4M)/
OS32C-SP1-DM(-4M))
(Per international standard IEC 61496-3, area scanners used in
applications where the angle of approach exceeds +/- 30 degrees
with respect to the detection plane, must use RBM in the detection
zone.)
New convenient and easy-to-use functions
Replacable sensor, no reprogramming needed
No reprogramming needed, the configuration is stored in
the I/O block. Replacing a damaged sensor is fast and easy.
Easy configuration of complex zones
The configuration of the safety zone and warning zones
can be done in real time using a PC. Configurations
can also be created or modified offline.
Reference Boundary Monitoring function
The OS32C constantly monitors reference points and
turns OFF the safety outputs when a shift in its position
is detected.
画面変更あり
4
5
Applications
Safety Output ON
Sensor Block
I/O Block
Safety Output OFF
Reference Boundary Monitoring function supports intrusion detection without physically blocking the entrance.
Supports various operation patterns by switching zone sets.
Arm detection can also be made possible by changing the minimum object resolution to 30, 40, 50 or 70 mm through
use of the configuration tool. However, the maximum size of the safety zone varies depending on the configured
minimum object resolution.
Safety zone can be selectedIntrusion detection with vertical installation
Intrusion Detection
Compact body allows for use inside the machine.
Detection angle of 270° provides coverage of two sides with one scanner.
Guarding inside the machine Presence detection of 270°
Presence Detection
Gap
occurs
Detachable
Small, light and compact body provides for easy installation on an AGV.
Low power consumption (5 W) reduces battery load on the AGV. (3.75 W in standby mode)
Up to 70 zone set combinations support complex AGV tracks.
All-around MonitoringFront/Rear monitoring
Collision Avoidance
Scanner Safety Outputs
EtherNet/IP
TM
for Status and Measurement Data
The OS32C system status, zone status, and measurement data can all be monitored over EtherNet/IP.
EtherNet/IP™ is the trademarks of ODVA.
Windows is registered trademarks of Microsoft Corporation in the USA and other countries.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.