Datasheet
OS32C
14
System Components and Functions
Main Unit
* For OS32C-SP1(-DM), each connector is located on the left as viewed from the back of the I/O block.
Status/Diagnostic Display
When powered up, the OS32C will display the configured minimum object resolution for 5 seconds, as indicated in the following table:
Number Component Function
(1) RUN indicator (green) Will turn ON when safety zone is clear and OSSDs are ON.
(2)
Interlock Indicator
(yellow)
Will turn ON when in interlock state, blink under lockout, and blink in case of a failure.
(3) Status/Diagnostic Display The scanner status, configuration/operation, or failure is displayed.
(4) Warning Output Indicator (orange) Will turn ON when the warning output is ON.
(5) STOP indicator (red) Will turn ON when safety zone is blocked, OSSD are OFF or under interlock state.
(6) Dust Ring Dust detection cover with reflective surface, for dust accumulation detection
(7) Individual Sector Indicators
Will turn ON when an intrusion is detected in the safety zone, 8 sectors total. Each sector =
33.75°.
(8) Scan window The window where the laser light is emitted and received.
(9) Ethernet Connector Used for Ethernet cable connection. *
(10) Power Connector 18-pin connector (pigtail). *
(11) I/O Block Connector module
(12) Center of rotation Indicates the location of the axis around which the laser emits.
(13) Sensor block Sensor head; field replaceable.
Digital Indication Minimum object resolution
L3 30 mm
L4 40 mm
L5 50 mm
L7 70 mm (factory default)
(1)
(5)
(8)
(10)
(9)
(11)
(13)
(12)
(7)
(6)
(2) (4)