Datasheet

Machine Automation Controller NX1P
6
* To use input refreshing with input changed time, the EtherCAT Coupler Unit with unit version 1.1 or later and the Sysmac Studio version 1.07 or
higher are required.
Digital Mixed I/O Units
Product Name
Specification
Model
Standards
Number of
points
Relay type
Maximum switching
capacity
I/O refreshing
method
ON/OFF response time
Relay Output Unit
(Screwless Clamping
Terminal Block, 12 mm
Width/24 mm Width)
2 points
N.O.
250 VAC/2 A (cosφ=1)
250 VAC/2 A (cosφ=0.4)
24 VDC/2 A
4 A/Unit
Free-Run
refreshing
15 ms max./15 ms max.
NX-OC2633
UC1, N, L,
CE, RCM,
KC
N.O.+N.C
. NX-OC2733
UC1, N,
CE, RCM,
KC
8 points N.O.
250 VAC/2 A (cosφ=1)
250 VAC/2 A (cosφ=0.4)
24 VDC/2 A
8 A/Unit
Free-Run
refreshing
15 ms max./15 ms max.
NX-OC4633
UC1, N, L,
CE, EAC,
RCM, KC
Product Name
Specification
Model
Standards
Number of
points
Internal I/O
common
Maximum value
of load current
I/O refreshing
method
ON/OFF response time
DC Input/Transistor
Output Unit
(MIL Connector,
30 mm Width)
Outputs:
16 points
Inputs:
16 points
Outputs: NPN
Inputs:
For both NPN/PNP
Outputs:
12 to 24 VDC
Inputs: 24 VDC
Switching
Synchronous I/O
refreshing and
Free-Run
refreshing
Outputs:
0.1 ms max./0.8 ms max.
Inputs:
20 μs max./400 μs max.
NX-MD6121-5
UC1, N,
CE, RCM,
KC
Outputs: PNP
Inputs:
For both NPN/PNP
Outputs: 24 VDC
Inputs: 24 VDC
Outputs:
0.5 ms max./1.0 ms max.
Inputs:
20 μs max./400 μs max.
NX-MD6256-5
DC Input/Transistor
Output Unit
(Fujitsu Connector,
30 mm Width)
Outputs:
16 points
Inputs:
16 points
Outputs: NPN
Inputs:
For both NPN/PNP
Outputs:
12 to 24 VDC
Inputs: 24 VDC
Switching
Synchronous I/O
refreshing and
Free-Run
refreshing
Outputs:
0.1 ms max./0.8 ms max.
Inputs:
20 μs max./400 μs max.
NX-MD6121-6
UC1,
N,
CE,
RCM,
KC