Datasheet

Machine Automation Controller NX1P
14
Cables / Connectors
*1. We recommend you to use the above Cable and RJ45 Connector together.
*2. We recommend you to use the above Cable and RJ45 Assembly Connector together.
Optional Products/Maintenance Products/DIN Track Accessories
*1. EtherCAT junction slaves cannot be used for EtherNet/IP and Ethernet.
*2. Industrial switching hubs cannot be used for EtherCAT.
*3. Use the NX-END02 End Cover only for the CPU Unit and the NX-END01 End Cover only for the EtherCAT Coupler Unit.
Item Recommended manufacturer Model
Products for EtherCAT or
EtherNet/IP
(1000BASE-T/100BASE-TX)
Wire Gauge and Number of
Pairs: AWG24, 4-pair
Cable
Cables
Hitachi Cable, Ltd.
NETSTAR-C5E SAB 0.5
×
4P
*1
Kuramo Electric Co. KETH-SB *1
SWCC Showa Cable Systems Co. FAE-5004 *1
RJ45 Connectors Panduit Corporation MPS588-C *1
Products for EtherCAT or
EtherNet/IP
(100BASE-TX/10BASE-T)
Wire Gauge and Number of
Pairs: AWG22, 2-pair
Cable
Cables Kuramo Electric Co. KETH-PSB-OMR *2
JMACS Japan Co., Ltd. PNET/B *2
RJ45 Assembly Connector OMRON
XS6G-T421-1 *2
Product Name Specification Model
Standards
EtherCAT junction
slaves *1
3 ports. Power supply voltage: 20.4 to 28.8 VDC (24 VDC -15 to +20%).
Current consumption (A): 0.08
GX-JC03
CE, UC1
6 ports. Power supply voltage: 20.4 to 28.8 VDC (24 VDC -15 to +20%).
Current consumption (A): 0.17
GX-JC06
Industrial Switching
Hubs for EtherNet/IP and
Ethernet *2
Quality of Service (QoS):
EtherNet/IP control data priority
Failure detection:
Broadcast storm and LSI error detection
10/100BASE-TX, Auto-Negotiation
3 ports. Current consumption (A): 0.22
Power supply connector included.
W4S1-03B
UC, CE
5 ports. Current consumption (A): 0.22
Power supply connector included.
W4S1-05B
5 ports. Current consumption (A): 0.22
Failure detection
Power supply connector and Connector for informing error
included.
W4S1-05C CE
Memory Cards
SD memory card, 2 GB HMC-SD291 N, L, CE
SD memory card, 4 GB HMC-SD491 CE
Battery
The battery is not mounted when the product is shipped.
To turn OFF the power supply to the equipment for a certain period of time by using the clock data for
programming, event logs, etc., you need a separately-sold battery to retain the clock data. Refer to the
Battery page for details.
CJ1W-BAT01 ---
End Cover
(For NX1P2 CPU Unit) *3
Must be connected to the right end of the CPU Rack.
One End Cover is provided with the CPU Unit.
NX-END02 ---
End Cover
(For EtherCAT Coupler
Unit) *3
One End Cover is provided with the EtherCAT Coupler Unit. NX-END01 ---
DIN Tracks
Length: 0.5 m; Height: 7.3 mm PFP-50N
---
Length: 1 m; Height: 7.3 mm PFP-100N
End Plate
There are 2 stoppers provided with CPU Units and I/O Interface Units as standard accessories to secure
the Units on the DIN Track.
PFP-M ---
Unit/Terminal Block
Coding Pins
For 10 Units
(Terminal Block: 30 pins, Unit: 30 pins)
NX-AUX02 ---
DIN Track Insulation
Spacers
A Spacer to insulate the control panel from the DIN Track.
To insulate the EtherCAT Slave Terminal from the control panel, use Din Track Insulation Spacers.
NX-AUX01 ---
Product Name
Specification
Model
Standards
No. of terminals
Terminal number
indications
Ground terminal mark
Terminal current
capacity
Terminal Blocks
8A/B
None
10 A
NX-TBA082
---
12 A/B NX-TBA122
16 A/B NX-TBA162
12 C/D NX-TBB122
16 C/D NX-TBB162
8A/B
Provided
NX-TBC082
16 A/B NX-TBC162