Datasheet
Machine Automation Controller NX1P
10
Communications Interface Units
IO-Link Master Unit
System Units
* Use the NX-PF0730 at 4 A or less on the CPU Rack where the NX1P2 CPU Unit is mounted.
Product Name
Serial interface
External connection terminals
Number of
serial ports
Communications protocol Model
Standards
Communications
Interface Unit
RS-232C
Screwless Clamping Terminal Block 1 port
• No-protocol
• Signal lines
NX-CIF101
UL, N, CE,
RCM, KC
RS-422A/485 NX-CIF105
RS-232C D-Sub connector 2 ports NX-CIF210
Product Name
Specification
Model
Standards
Number of
IO-Link ports
I/O refreshing method I/O connection terminals
IO-Link Master Unit
4
Free-Run refreshing
Screwless clamping terminal block NX-ILM400
UC1, N,
CE, RCM,
KC
Product Name Specification
Model
Standards
Additional NX Unit
Power Supply Unit
Power supply voltage: 24 VDC (20.4 to 28.8 VDC)
NX Bus power supply capacity: 10 W max.
NX-PD1000
UC1,
N, L,
CE, RCM,
KC
Additional I/O Power
Supply Unit
Power supply voltage: 5 to 24 VDC (4.5 to 28.8 VDC)
I/O power feed maximum current: 4 A
NX-PF0630
UC1,
N, L,
CE, RCM,
KC
Power supply voltage: 5 to 24 VDC (4.5 to 28.8 VDC)
I/O power feed maximum current: 10 A *
NX-PF0730
I/O Power Supply
Connection Unit
Number of I/O power terminals: IOG: 16 terminals
Current capacity of I/O power terminal: 4 A/terminal max.
NX-PC0010
UC1,
N, L,
CE, RCM,
KC
Number of I/O power terminals: IOV: 16 terminals
Current capacity of I/O power terminal: 4 A/terminal max.
NX-PC0020
UC1,
N, L,
CE, RCM,
KC
Number of I/O power terminals: IOV: 8 terminals, IOG: 8 terminals
Current capacity of I/O power terminal: 4 A/terminal max
NX-PC0030
UC1,
N, L,
CE, RCM,
KC
Shield Connection
Unit
Number of shield terminals: 14 terminals
(The following two terminals are functional ground terminals.)
NX-TBX01
UC1,
N, L,
CE, RCM,
KC