NX-Series Modular I/O System Connecting to Open Industrial Network Standards » Choice of functionality and performance.
Choice of networks The NX-series Communication Coupler Units support global open networks. Select the network that best suits your needs. Lineup of Communication Coupler Units EtherNet/IP Communication Coupler Unit EtherNet/IP uses the Common Industrial NX-EIC202 Protocol (CIP TM) over a standard Ethernet infrastructure. The EtherNet/IP Coupler has a built-in Ethernet switch and two RJ45 ports, to daisy-chain I/O stations without additional hardware.
NX Series The NX Series is a range of modular designed units that integrate standard I/O and safety and connect to the EtherNet/IP network via Communication Coupler Units. INDE X Features 1. Integrated control Standard I/O and safety units can be mixed within an I/O station. 2. Integrated design environment Machine and safety control can be >P >P IEC 61131-3 function blocks for safety control, as recommended by PLCopen, are supported. 4.
Distributed I/O: the choice is yours. The modern remote I/O demands increasing levels of flexibility. The EtherNet/IP Communication Unit enables connection between the CJ-series or other Programmable Controller and NX-series I/O through EtherNet/IP, which expands system configuration possibilities.
Various PLC vender like CJ series Up to 63 Units per communication ation coupl coupler Ty Types of standard NX I/O Units N • Digital Input/Output Units Input/Output Units • Temperature Input Units • Encoder/Positioning Units • Power supply and connection Units • Analog Quick connections • Detachable screwless terminal block for easy commissioning and maintenance • Push-in connections speed up installation • MIL connectors for high-density I/O Safety Integrated The NX-series safety controller and I/O
The Safety solution for any application As machine automation evolves the need for diversity in configurations will increase. OEM’s and end-users need the ability to design highly flexibly system that have safety and can integrate with a variety of PLC’s to meet the demands of evolving automation.
Safety Control Units • EN ISO13849-1 (PLe/Safety Category 4), IEC 61508 (SIL3) certified. • 4 or 8 points per Safety Input Unit. 2 or 4 points per Safety Output Unit. • The Safety Units can be freely allocated in any combination with standard NX I/O. Modular design • Small system size allows space savings in the cabinet. ISO 13849-1, PLe • Direct Diagnostic with LED's. IEC 61508, SIL3 • Easy wiring and easy to maintain.
One I/O system for various controllers. While different machines may require different levels of controller performance, NX-series is the only remote I/O system you will need. This will unify wiring and Low-end Machine installation techniques, and simplify spare parts stock. Safety control programs that are created using the NX I/O Edition can be standardized and reused throughout the machine portfolio, which will reduce the time required for development, testing and certification.
Same Manner for Safety Design Common Software & Common Hardware High-performance Machine Automation Software Sysmac Studio Full edition Machine Automation Controller NJ series Integrated Safety System AC Servo motor/Driver
NX-series EtherNet/IP Coupler Unit NX-EIC Connecting to open industrial network standard EtherNet/IP • The EtherNet/IP Coupler Unit is the link between the EtherNet/IP multivendor network and the NX-series I/O Units and Safety Units. With wide variety of the I/O Units and Safety Units, the NX-series is the perfect match for the CJ-series and multivendor Controllers. Features • Up to 63 NX-IO Units can be connected to one EtherNet/IP Coupler Unit. Standard and high-performance units can be mixed.
NX-EIC Ordering Information International Standards • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives, and KC: KC Registration. • Contact your OMRON representative for further details and applicable conditions for these standards.
NX-EIC Recommended EtherNet/IP Communications Cables Use STP (shielded twisted-pair) cable of category 5 or higher for EtherNet/IP.
NX-EIC Accessories End Cover (NX-END01) One End Cover is provided together with the EtherNet/IP Coupler Unit.
NX-EIC EtherNet/IP Coupler Unit Specifications Item Specification Model NX-EIC202 Number of connectable NX Units 63 Units max.
NX-EIC Item Specification Installation orientation: 6 possible orientations Restrictions: • Used in the upright installation orientation. Unit power supply [W] 10 W output, 40°C 12 10 8.5 W output, 55°C 8 6 4 2 0 0 10 20 30 40 45 50 55 60 Ambient temperature [°C] • Used in any other orientation than the upright installation orientation. Unit power supply [W] 10 W output, 40 °C 12 10 Installation orientation and restrictions 8 6.
NX-EIC Item Specification Peripheral USB port Internal circuits IN communications connector OUT communications connector UV UV UG Circuit layout Terminal block UG UNIT PWR LED Non-isolated power supply circuits NX Unit power supply − I/O power supply + IOV IOG NX Unit power supply + NX bus connector I/O power supply − I/O PWR LED DIN Track contact plate A1 B1 UV UV UG UG IOV IOG Unit power supply (24 VDC) Terminal arrangement I/O power supply (5 to 24 VDC) Ground to 100 Ω or less.
NX-EIC Configuration Unit Refer to the user's manuals for information on the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit.
NX-EIC External Interface EtherNet/IP Coupler Unit NX-EIC202 (A) (B) (D) NX-EIC202 (C) (E) F 012 789A 3456 D BC E F 012 789A 3456 (F) D BC E NET (C) (G) Letter (A) Name Function NX bus connector This connector is used to connect the EtherNet/IP Coupler Unit to the NX Unit on the right of the Coupler Unit. The indicators show the current operating status of the Unit and the status of the power supply.
NX-EIC Applicable Wires Using Ferrules If you use ferrules, attach the twisted wires to them. Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules. Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules. The applicable ferrules, wires, and crimping tool are given in the following table.
NX-EIC Dimensions (Unit: mm) ● EtherCAT Coupler Unit Only 48.1 46 0.55 1.5 NX-EIC202 F 012 789A 3456 D BC E 789A F 012 104.5 100 3456 D BC E NET 1.5 65.2 71 80 ● With Cables Connected *1 100 to 120 *2 5.8 71 USB cable Communications cable *1. This dimension depends on the specifications of the commercially available USB cable. Check the specifications of the USB cable that is used. *2. This is the dimension from the back of the Unit to the communications cables.
NX-EIC ● End Cover 12 1.5 100 1.5 71 Related Manuals Man. No Model Manual Application Description Learning how to use an NXseries Ether-Net/IP Coupler Unit and EtherNet/IP Slave Terminals Introduces the system, configuration methods, Unit hardware, setting methods, and functions of EtherNet/IP Slave Terminals that consist of an EtherNet/IP Coupler Unit and NX Units.
MEMO 22
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.