Datasheet
28 Remote I/O
AG
A1 B1
A8 B8
AG
AG
AG
Input +
Input
Input1+
Input1
Input2+
Input2
Input3+
Input3
Input4+
Input4
NX-AD3604/NX-AD3608
NX-AD4604/NX-AD4608
A1 B1
A8 B8
Input1+
Input1
Input2+
Input2
Input3+
Input3
Input4+
Input4
Input5+
Input5
Input6+
Input6
Input7+
Input7
Input8+
Input8
Input +
Input
A1 B1
A8 B8
AG
NC
AG
NC
Input +
Input
Input1+
Input1
Input2+
Input2
Terminal wiring
NX-AD2604/NX-AD2608
Circuit layout
NX-AD2604/NX-AD2608
AMP
AG
AG
510 KΩ
510 KΩ
Input1+ to 2+
Terminal block
I/O power supply +
I/O power supply
I/O power supply +
I/O power supply
Input1 to 2
AG: Analog circuit internal GND
NX-AD3604/NX-AD3608
AMP
AG
AG
Input1+ to 4+
Terminal block
I/O power supply +
I/O power supply
I/O power supply +
I/O power supply
Input1 to 4
510 KΩ
510 KΩ
AG: Analog circuit internal GND
NX-AD4604/NX-AD4608
AMP
AGAG
Input1+ to 8+
Terminal block
I/O power supply +
I/O power supply
I/O power supply +
I/O power supply
Input1 to 8
510 KΩ510 KΩ
AG: Analog circuit internal GND
NX bus
connector
(left)
NX bus
connector
(right)
NX bus
connector
(left)
NX bus
connector
(right)
NX bus
connector
(left)
NX bus
connector
(right)
Voltage input unit
NX-AD260
@
AG terminal is connected to 0 V of analog circuit inside the unit.
It is not necessary to wire AG terminal normally.
Voltage input unit
NX-AD360
@
AG terminal is connected to 0 V of analog circuit inside the unit.
It is not necessary to wire AG terminal normally.
Voltage input unit
NX-AD460
@