Datasheet

34
NSH5 Series
A hand-held version of the NS5 is now available to perform operations at the production site. The
NS-series PT's have a complete set of functions that can be used at the production site, such as
the SAP Library, multi-language support, and Programming Console functions.
Precautions for Emergency
Stop Switches
When using a hand-held NSH5 that will be installed
and removed from a control panel or Removable Box,
always use the specified Stop Switch
(Gray/NSH5-SQG10B-V2) to conform to Safety
Standards (EN 60204-1).
Function Switches
Emergency Stop Switch.
Water Resistance to IP65
PT and Cable Sold Separately
Options
Removable Box
A separate external circuit is not required because the
Removable Box has been configured so that the
emergency stop switch line will not turn OFF (i.e., so that
the emergency stop circuit will operate) even when the
NSH5 is removed.
Visor
Use when the NSH5 is in direct sunlight.
Mounting Bracket
Use to attach the NSH5 to a control panel.
3-Position
Enable Switch
Memory Card Interface and
USB Slave Connector.
Use the ten functions
switches.
F1, F2, F6, F7: Wired outputs
F3 to F5, F8 to F10:
Communications outputs
Increased safety with
DPST-NO structure (wired
outputs).
Select the Cable according to the
application (RS-232C/RS-422A).
Connector-loose wires,
UL connector,
3 m or 10 m.
The water-resistant structure is equivalent
to IP65 on all surfaces. The PT may not be
suitable for use in environments with
long-term water exposure.
3PST-NC Structure
DPST-NC: Increase safety (wired outputs).
SPST-NC: Input to internal NSH5 memory,
output to a lamp for emergency stop switch
operation, or output via communications,
e.g., to a PLC.
Easily transfer screens or save logs at high
speed using a USB connection.