P rog ra m m ab le Te rmina ls NS Series NS, the HMI brand you can rely on » Proven Reliability » Best Match » Machine Management
NS, the HMI brand you can rely on Machine Control at Your Fingertips. On-screen Machine Management. Expanding markets in emerging countries, short product cycles, and diversifying customer needs are just some of the factors that create drastic Let Your Machines Evolve changes for the production industry.
The Best Match Possible Machine Management Tool Proven Reliability The amount of work and cost of connecting to The machine designer can easily implement In the ten years since initial marketing, OMRON PLCs and components have been PLC troubleshooting, machine troubleshooting, OMRON has globally supplied numerous HMI greatly reduced.
NS Series Lineup This powerful lineup showcases OMRON's unique value. Choose from 3 types to match your application and requirements. NS Series Standardd Models 15 Plentiful scree screen variations and diverse functions allow usee in a wide variety of applications. inches Color TFT NS15-TX 12.
NSJ Series Integrated Controller oller Models 12.1 PT is unified with the t Controller into one package to greatly help standardize equipment and reduce size. inches Color TFT NSJ12-TS NSJ12 -G5D 10.4 inches Color TFT 32,768 colors SVGA 800 x 600 pixels Screen memory size: 60 MB USB Slave Ethernet USB Master RS-232C x 3 USB Slave Ethernet USB Master RS-232C x 3 NSJ8 TV NSJ8-TV V -M M3 3D -M3D 8.
A Revolutionary Best Ma The NS-series PTs provide revolutionary compatibility with the road-proven CS/CJ-series the new NJ-series Controllers to achieve even greater added value in user machines. The NJ-series Machine Automation Controllers Revolutionize Productivity You can create a flexible, high-speed, high-precision system based on the NJ-series Machine Automation Controllers.
tch PLCs and The CS/CJ-series PLCs for the Reliability of a Proven Track Record Features are provided to easily connect to CS/CJ-series PLCs to take advantage of their proven track record. Many features that do not require screen creation or programming support everything from design through maintenance to take advantage of the compatibility of OMRON PLCs and PT and to serve as the face of your machines.
Power Support for All User From conceptual designs through commissioning, operation, and maintenance, the NS Design Reduced work For Machine Automation Controllers NJ-series P10 NJ Troubleshooter Integrated NS-series PT simulation P 11 Troubleshooter P 19 Plentiful Graphing Functions PLC Troubleshooter Machine Troubleshooter Best Match with OMRON Products Screen Data Security Functions P12 - P16 Smart Active Prarts (SAP) P 20 P 20 Device Data Transfer With EtherNet/IP Direct Connection to Te
Needs Series supports every user need.
For Machine Automation Controllers NJ-series Use Integrated NS-series PT simulation or NJ troubleshoot by using the NS-series PTs to make the most of the strengths of the NJ-series Controllers and to manage machines. NJ Troubleshooter Controller Errors Standard Feature for NJ-series Controllers Errors are automatically detected and displayed on-screen along with corrective actions for the CPU Unit function modules, EtherCAT slaves, and CJ-series Units that are connected in the NJ-series Controller.
Design Startup/Operation Troubleshooter A Troubleshooter is provided for the connected OMRON Controller or PLC. This greatly reduces work requirements. Maintenance CS/CJ-series PLC Troubleshooter Constantly monitors PLC errors. NS-Run NS-Runtime untim timee Automatically detects PLC errors and displays the error details and recovery procedure on the screen. Even if a problem occurs, it can be resolved quickly without referring to the manuals.
Best Match with OMRON Products NS Series is the most suitable HMI for the system that comprises OMRON components. The advantage is the "compatibility (reducing programming and screen data creation work)" which will reduce the amount of designing work.
Design The Temperature Controller's setting and monitor screens are completed in no time. Startup/Operation Smart Active Parts (SAP Library) Dramatically reduces the effort required to create ladder programming and screens. SAP Library, Temperature Controller Parts Maintenance More than 3,000 Library parts (Smart Active Parts) are available, which can directly access OMRON PLCs and components.
Design EtherNet/IP Startup/Operation Simultaneous and parallel engineering The host applications can be designed using the tag names of the PLC and PT. Parallel development will shorten the design time. Support for data structures This special feature is made possible by combining an OMRON CJ2 PLC with an NS-series PT. The data structures that you define on the Programming Tool can be used on the CX-Designer simply by dragging and dropping them.
Design EtherNet/IP Startup/Operation Simultaneous and parallel engineering The host applications can be designed using the tag names of the PLC and PT. Parallel development will shorten the design time. Support for data structures This special feature is made possible by combining an OMRON CJ2 PLC with an NS-series PT. The data structures that you define on the Programming Tool can be used on the CX-Designer simply by dragging and dropping them.
Direct Connection to Temperature Controllers Connect OMRON Temperature Controllers directly to the NS-series PT. OMRON Temperature Controllers can be connected directly to the NS-series PT's RS-232C port. Data does not pass through the PLC, so ladder programming is not required. Also, there are plenty of objects in the SAP Library for Temperature Controllers, and Temperature Controller screens can be created easily just by pasting objects from the SAP Library to the screens.
Design Support 42 languages and switch the language of the labels among up to 16 languages. Startup/Operation Multi-language Support Multi-language CSV data The labels' text attributes can also be reflected when importing. Maintenance When screen data is imported, text attributes can be applied to the specified labels and attributes such as the font and text color can be reflected to other languages labels. Unicode is supported and 42 Asian and European languages can be combined in screens.
Multiple functions Multifunction execution with one object Execute up to 32 functions with one Multifunction Object Multifunction Objects support Write Bit, Write Word, object control, and etc Multifunction Objects combine the functions of multiple objects into one object. Multiple functions can be executed by pressing one button without using troublesome macros. Setup is easy.
Design Startup/Operation Plentiful Graphing Functions Data Log Graph (Trend Graph) Up to 128 data can be collected in the cycle of 500ms. Logging data is stored as a CSV file in the Memory Card inserted in the NS-series PT. The log data files in the Memory Card appear as shown below when the read file button is pressed. Maintenance Logging data is stored as a CSV file in the Memory Card mounted in the NS-series PT. The data stored in the Memory Card can be read or deleted from the screen.
Screen Data Security Functions Security password Protect important screen data with a password. A password between 4 and 64 characters long can be set. The download/upload will start if the user inputs the password that was set when the screen was designed. (Password input will be disabled if the wrong password is input 3 times in a row.
Design NEW Easy Reading from Palette Startup/Operation NS Screen Templates The CX-Designer of version 3.5 or higher provides the palette to display objects and templates (scheduled for auto update in August 2012). Refer to the next page for details of the palette. Even Simpler Maintenance Templates can be read into the screen by just dragging and dropping thumbnails displayed on the palette.
Screen Designer for NS Series, CX-Designer User-friendly Screen Creation Without screen creation and ladder programming, the CX-Designer Screen Design Software is so easy-to-use that anyone can master it. Quickly create the required screen by dragging and dropping objects. OMRON’ s unified development environment lets you drastically reduce the work required to create screens. Note: The same type of Project Workspace and Output Window as in the CX-Programmer are provided for the user interface.
Design NEW Startup/Operation Palette Switches, lamps, and templates are registered in the palette. Just drag and drop them on the new or existing screen to add. Note. CX-Designer version 3.5 or higher is required. Maintenance Import The Import button allows new objects and templates to be added to the palette. The palette appears on the right side of the screen when starting the CX-Designer.
Reading Another Project's Screens and Objects Resources from another project can be easily reused by just selecting the screen or objects that you want to read and dragging and dropping it, so screens can be created intuitively. Example screen 1 Select the screen that you want to read, drag it to the destination, and drop it. Example screen 2 Select the part that you want to read, drag it to the destination, and drop it.
Design CX-Programmer's symbol table Maintenance The symbol table created in the CX-Programmer during ladder programming can be read into the CX-Designer by dragging and dropping, so it isn't necessary to manually data such as input addresses and I/O comments. Tags (i.e., network symbols) can also be read into the CX-Designer. Startup/Operation Reading the Symbol Table Note: Version 8.0 or higher of the CX-Programmer support tags (i.e., network symbols).
0,000-color Video Display Equipment and workpiece movements can also be displayed in beautiful video NS-CA001 Video Input Unit Four video inputs or CCD cameras can be connected and up to four images can be displayed simultaneously if the image size is 320x240 pixels. The NS-CA001 cannot be used with the NS5 or the NS15. NS-CA002 RGB/Video Input Unit There is an analog RGB input terminal in addition to the two video input terminals.
Design Startup/Operation FTP Function You can partially replace text and pictures from your computer. Maintenance FTP (File Transfer Protocol) has been added! Texts, lists, and recipes can be replaced with the put/get command from your computer! You can even replace BMP files from your computer easily.
Comparison NEW The on-site NS screen can be compared with the computer screen. Same Different Added Deleted The comparison function of the CX-Designer enables the following comparison. CX-Designer project Project in the computer CX-Designer project NS project Same in screen Different in screen Screen added Screen deleted PT Transfer Compare Comparison Comparison result Single Port Multi Access (SPMA) Note: Communications across network layers can be performed. Keep connected.
Design Startup/Operation PLC Data Trace The PLC data trace function can be used without a computer. Maintenance The PLC Data Trace function is built into the PT in addition to the Ladder Monitor and Device Monitor. A bit's status and operation can be viewed in a time chart just by setting the desired PLC bit's address in the PT. It is also now possible to display word data, save data in CSV files, and save time chart screens in BMP files.
Ladder Monitor The ladder program can be monitored without a computer. Ladder programs with I/O comments can be monitored on the PT's screen and the ladder program can also be edited with the Programming Console function. Operation screen CS/CJ/CP-series PLC Also meets the requirements of users who need to display devices onsite Switch Box Function Device Monitor Function Switch Box Function The operator can check the PLC status by displaying just the I/O comments and status.
Design Startup/Operation “Find Back”, “Find Next”, useful Function Supported by the NS-series. Reduced Time to Investigate Which Output or Input Is Causing the Problem. Function Operationn with NS-series PT. CX-Programmer Find the address at specified by the cursor. Next “N” Key uble-cliick Double-click Return to the previous search position. Maintenance Find the output from the input bit or find the input bit from the output at the cursor. “Space” Key “B” Key Backk NS-Runtime 1.
NS-Runtime NS-NSRCL (NS-Runtime) Achieve machine/line monitoring and data logging on your office computer. Machine Viewer Displaying Maintenance Information (PDF File) Monitoring Device Alarms Machine monitoring in an office environment. There is no need to create complex host applications. Moreover, when an alarm occurs, a PDF file can be displayed as maintenance information.
Design Startup/Operation Recipe Handling Maintenance NS-Runtime Checking machine data or switching processes from a host computer is easy. Parameter groups in the PLC can be transferred together to a computer, and the transferred data can be checked and edited in CSV format, e.g., using Excel. The edited data can then be transferred together back to the PLC.
NSH5 Series A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's have a complete set of functions that can be used at the production site, such as the SAP Library, multi-language support, and Programming Console functions. Function Switches Use the ten functions switches. F1, F2, F6, F7: Wired outputs F3 to F5, F8 to F10: Communications outputs Memory Card Interface and USB Slave Connector.
Programmable Terminals NS Series Even Simpler Equipment Operation with Outstanding Synergy. 5.7 inches 10.4 inches 15 inches 12.1 inches 8.4 inches Color TFT Color TFT Color TFT Color TFT Color TFT STN monochrome Features • 5.7 to 12.1 inch sizes are available. • A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's have a complete set of functions that can be used at the production site.
NS Series Network Provides serial NT Link communications supporting both 1:1 and 1:N connections. The NT Link has more efficient communications than Host Link and its capabilities are especially apparent in applications with multiple PTs connect to the PLC. The NS-series PTs can also support communications with multiple PLCs and multiple NS-series PTs through Controller Link and Ethernet connections, so the network can be configured freely to match the requirements and scale of the application.
NS Series Configuration of CS series, CJ series and CP series 2 Serial connection 1:1 NT Link or Host Link NS:PLC = 1:1 NS:PLC = 1:2 Connecting with the PLC through port A or port B NS-series PT NS-series PT PLC PLC PLC 1:N NT Link NS:PLC ratio = 8:1 max. Up to 8 NS-series PTs can be connected to each of the PLC's RS-232C/RS-422A ports. NS-series PT NS-series PT NS-series PT PLC NS-AL002 Converter (Converts between RS-232C and RS-422A.
NS Series System Configuration NS5/NS8/NS10/NS12/NS15 OMRON Memory Card Memory Card Interface Ethernet port USB Slave RS-422A Conversion Unit CJ1W-CIF11 NS-AL002 Note: A Conversion Unit is not required to connect to the RS-422A/485 serial interface of the NS15.
NS Series Expansion Bus Interface Any one of the following Units can be mounted to the expansion bus interface. Controller Link Interface Unit NS-CLK21 Video Input Unit NS-CA001 RGB/Video Input Unit NS-CA002 Expansion bus interface Controller Link PLC NTSC/PAL Vision Sensor NTSC/PAL RGB output Note: Video Input Units and RGB Video Input Units cannot be used with some models.
NS Series NSH5 Hand-held PT USB Commercially available USB cable.
NS Series Ordering Information International Standards • The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards.
NS Series Software ●How to Select Required Support Software for Your Controller The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
NS Series Cable Product name Cable *1 NSH5 Cables UL-compliant NSH5 Cable PT-to-PLC Connecting Cable *2 NSH5 Removable Box Cable Specifications Model Screen transfer cable for DOS/V (CX-Designer ↔ PT) Length: 2 m XW2Z-S002 USB-Serial Conversion Cable Length: 0.
NS Series Options Product name Video Input Unit Specifications Model Inputs: 4 channels Signal type: NTSC/PAL Standards NS-CA001 UC1, CE Input channels: 2 video channels and 1 RGB channel *1 Signal type: NTSC/PAL NS-CA002 For Controller Link Communications NS-CLK21 Transmission distance: 500 m total length Note: Use this model when connecting PT models without a V@ suffix. Note: PT models with the V@ suffix can also be connected.
NS Series General Specifications NS5/NS8/NS10/NS12/NS15 Series Rated power supply voltage NS5-V2 NS8-V2 NS10-V2 NS12-V2 NS15-V2 24 VDC Allowable voltage range 20.4 to 27.6 VDC (24 VDC ±15%) Power consumption 15 W max. Ambient operating temperature 0 to 50 °C (See note on the next page.) Note: The ambient operating temperature is subject to the following restrictions according to the mounting angle.
NS Series Performance/Specifications NS5 Series NS5-V2 Model NS5-SQ10-V2 NS5-SQ11-V2 NS5-SQ10B-V2 NS5-SQ11B-V2 NS5-TQ10-V2 NS5-TQ11-V2 NS5-TQ10B-V2 NS5-TQ11B-V2 Built-in Ethernet port No Yes No Yes No Yes No Yes Case color Ivory Display device TFT color LCD Effective display area Width 117.2 × height 88.4 mm (5.
NS Series NS8/NS10/NS12/NS15 Series NS8-V2 NS8NS8TV01- TV00B V2 -V2 Yes No Black Display device High-definition TFT color LCD High-definition TFT color LCD High-definition TFT color LCD Effective display area Width 170.9 × height 128.2 mm (8.4 inches) Width 215.2 × height 162.4 mm (10.4 inches) Width 246.0 × height 184.5 mm (12.
NS Series Communications NS5/NS8/NS10/NS12/NS15 Memory Card Interface One ATA-Compact Flash interface slot Functions Used to transfer and store screen data, store logging data, and store history data. (Alarm/Event History, Operation Log, and Error Log generated during Macro execution). Connector Conforms to EIA RS-232C. D-Sub female 9-pin connector 5-V output (250 mA max.) through pin 6. The 5-V outputs of serial ports A and B cannot be used at the same time.
NS Series Connectable Devices Supported OMRON PLCs PLC series C Series CVM1/CV Series CS Series CJ Series CP Series PLC model name RS-232C *1 1:1 NT Link Ethernet 1:N NT Link Host Link FINS *2 EtherNet/IP *3 Controller Link *4 CQM1 Yes No Yes No No No CQM1H Yes Yes Yes No No Yes CPM1 Yes No Yes No No No CPM1A Yes No No No No No CPM2A Yes No Yes No No No CPM2C Yes No Yes No No No C200HS Yes No Yes No No No C200HE (-Z) Yes Yes Yes No No Yes
NS Series Function Comparison PLC series C series CVM1/CV series PLC model name Ladder Monitor Device Monitor/ Switch Box PLC Data Trace SPMA SAP NJ EtherNet/IP Troubleshooter/ Tag access PLC Integrated (Network Troubleshooter NS-series PT symbols) simulation *4 CQM1 No No No No No No No CQM1H No No No No No No No No CPM1 No No No No No No No No CPM1A No No No No No No No No CPM2A No No No No No No No No CPM2C No No No No No No No No C200HS No
NS Series Connectable Inverters Series 3G3MX2-V1 Communication Unit Connection (Use the RS-485 terminal on the Inverter) 3G3JX (Use the RS-485 connector on the Inverter) 3G3RX-V1 (Use the RS-485 terminal on the Inverter) RS-485 (2-wire) 1:N Connectable Temperature Controllers The following Temperature Controllers can be connected directly to an NS-series PT*.
NS Series Connecting to Another Company’s PLC Manufacturer Series A Series FX Series Mitsubishi Electric Q/QnA Series CPU Computer Link Unit A1SJ71UC24-R@ A1SJ71UC24-PRF A2ACPU Computer Link Unit AJ71UC24 FX0N FX1S FX1N FX1NC FX2N FX3UC FX3G Communication special adapter FX3U-232-ADP FX2NC-232ADP FX0N-232-ADP Connection diagram RS-232C, RS422A/485 *1 1:1 RS-232C, RS422A/485 *1 1:1 RS-232C 1:1 RS-232C, RS-485 (4-wire) *2 1:N Communication expansion board FX@@-232-BD Q00CPU Q01CPU RS-23
NS Series Component Names and Options NS15 RS-422A/485 Serial Interface Memory Card interface Memory Card Note: Colors shown in photographs and product names may differ from actual colors and names. Expansion interface Battery Analog RGB Output RS-232C serial port A RS-232C serial port B A bar code reader can be connected to the serial port.
NS Series NS5 Memory Card interface Memory Card Note: Colors shown in photographs and product names may differ from actual colors and names. Expansion interface Ethernet (10 Base-T or 100 Base-TX) USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer) Battery Power Supply (24 VDC) RS-232C serial port A RS-232C serial port B A bar code reader can be connected to the serial port.
NS Series Dimensions (Units: mm) NS15 170 Mounting Panel Mounting Bracket 79.54 13.95 94.8 RUN RDA RDB SDA 46 SDB 27.4 282 304.5 304 71.8 RSA RSB 57.31 3.8 86.83 85.6 8 405 37.9 (min.) 41.1 (max.) 39.4 84.1 70 75.8 Recommended Panel Cutout Dimensions 15.5 340 383 405.5 +1 282.5 −0 383.5 +1 −0 NS12/10 Recommended Panel Cutout Dimensions 140 241 228 +1 −0 SW 227 249 RESET 121 24V DC PORT B HOST 134 PORT A SLAVE ETHERNET 15.5 264 315 323 7.5 39 (min.) 48.5 42 (max.
NS Series Hand-held NS5 16.5 223 70.5 75 50 176 75 81.3 9.6 164 (169) 9.6 164 (169) (1.9) 127.3 50.3 68.3 86.3 104.3 9.7 20.4 11 (102.7) 151.5 (183) 21.4 5 (22.3) 10.6 81.3 (102.7) 21.4 (1.9) NS-CLK21 Controller Link Interface Unit NS-CA002 Video Input Unit NS-CA001 Video Input Unit 31.5 9.7 (22.3) 11.1 5 5 164 20.4 11 (1.9) 39.3 57.3 82.8 118.3 (169) 10.8 (33.9) 32 11 95.6 Related Manuals Cat. No.
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.