User Manual

F03-16PE/-16PT/-15/-16PS
21
Sensing Band/Point Sensor
SUS316 used for core and polyethylene used for sheath to ensure high
resistance to both acidic and alkaline liquids.
Sensing Band Stickers that use the same material as the Sensing Band's
insulating resin are available in 2 types: adhesive-tape type and screw type.
Ordering Information
Specifications
Dimensions
Sensing Band
F03-16PE
(Unit: mm)
Sensing Band Stickers
F03-26PEN (screws)
(Unit: mm)
F03-26PES (adhesive tape) (Unit: mm)
*
The shape of the adhesive tape shown above is for securing the F03-16PE.
Compared to the F03-16PE (polyethylene), the F03-16PT has higher
resistance to both high temperatures and chemicals.
Detection precision remains constant even with a loopback, thanks to a two-
sided detection design.
Ordering Information
Specifications
Dimensions
Fluoroplastic Sensing Band
F03-16PT
(Unit: mm)
Fluoroplastic Sensing Band Stickers
F03-26PTN (screws)
(Unit: mm)
Chemical Resistivity
Name Model number
Liquid Leakage Sensing Band F03-16PE
Sensing Band Stickers
F03-26PES
F03-26PEN
Sheath Polyethylene
Core SUS316 stainless steel
Ambient operating temperature 15 to 55°C
Weight Approx. 16 g (1 m)
Appearance
Structure
Appearance
Structure
Appearance
Structure
F03-16PE
Liquid Leakage
Sensing Band
20
4
1.2
1.7
8
Materials: Electrodes: SUS316 stainless steel, Sheath: Fluoroplastic
22
Two, 3.5 dia.
Cut section
55
6.5
6.5
3.0
1.0
32
Material: Polyethylene
19.2
12
Adhesive tape *
5
Material: Polyethylene
Name Model number
Fluoroplastic Sensing Band F03-16PT
Fluoroplastic Sensing Band Stickers
F03-26PTN
Sheath PTFE fluoroplastic
Core SUS316 stainless steel
Ambient operating temperature –50 to 200°C
Weight Approx. 16 g (1 m)
Appearance
Structure
Appearance
Structure
F03-16PT
Fluoroplastic
Sensing Band
1.2
1.7
2.75
10
19/0.12x0.6t
SUS316
Materials: Electrodes: SUS316 stainless steel, Sheath: Fluoroplastic
25
15
Two, 3.5 dia.
12
3.0
Material: Fluoroplastic PFA
Note: 1. The F03-16PE Sensing Band is
made from the following materials.
Core: SUS316
Insulated sheath: Polyethylene
2. In order to prevent secondary fire
damage, consider the effect of the
atmosphere of the environment and
the solution to be detected on the
Sensing Band.
3. If the Sensing Band changes shape
or color when a liquid is detected,
replace the Sensing Band.
A: Not affected at all or only very slightly affected. B: Slightly affected but, depending on the conditions, sufficient for use.
C: Affected but may still be used. (Replace the Sensing Band immediately after detection.)
Polye
thylene
SUS316
Fluoro
plastic
Water AAA
Acetone CAA
Ammonia AAA
Ethanol BAA
Hydrochloric acid
ACA
Hydrogen
peroxide solution
AAA
Xylene BAA
Cyclohexane C---A
Trichloroethylene
CAA
Polye
thylene
SUS316
Fluoro
plastic
Toluene CBB
Phenol BAB
Butanol B --- A
Fluorine ACA
Hexane C --- A
Benzene CAA
Methanol BAA
Sulfuric acid CBA
Phosphoric acid
ABB