New Product Liquid Leakage Sensor Amplifiers K7L Series Reliable Sensitive Liquid Sensors for Stable Detection of Liquid Chemicals with Low Conductivity and Water Leakage • A lineup of new models compatible with Push-In Plus Terminal Sockets is available. • UL listed when used with Push-In Plus Terminal Sockets. • Sensor disconnection detection (K7L-AT50D@@/UD@@). • Models for long-distance wiring to 400 m. • Ribbon Electrode Bands and Point Sensors available.
Liquid Leakage Sensor Amplifier/Liquid Leakage Sensor Amplifier with Disconnection Detection Function K7L-AT50@/AT50D@@ Reliable Detection of a Wide Variety of Liquids Ranging from Water to Liquid Chemicals with Low Conductivity. Four Sensing Ranges Available. • A lineup of new models compatible with Push-In Plus Terminal Sockets is available. • Series of plus common connection compatible products added. *1.
K7L-AT50@/AT50D@@ Multi-channel Applications Detection of Condensation and Liquid Leakage at Semiconductor Production Installations Isolation between the power supply circuits and sensing circuits allows multiple channels to be installed in the same location. Detection is also possible for condensation inside cleaning devices and liquid leaked to the surroundings.
K7L-AT50@/AT50D@@ Ordering Information Product name Model K7L-AT50 Liquid Leakage Sensor Amplifier *1 K7L-AT50B K7L-AT50D Amplifier K7L-AT50DP Liquid Leakage Sensor Amplifier with Disconnection Detection Function *1 K7L-AT50DB K7L-AT50DPB F03-15 F03-16PE Sensing Band F03-16PT Sensors F03-16SF F03-16SFC F03-16PS Point Sensor (for K7L-AT50/AT50B) F03-16PS-F F03-25 F03-26PES Sensing Band Stickers Mounting Brackets and Stickers F03-26PEN F03-26PTN Socket *2 (for K7L-AT50/AT50D) Socket *2 (for
K7L-AT50@/AT50D@@ Nomenclature and DIP Switch Settings K7L-AT50/AT50D/AT50DP PW OMRON Corporation K7L-AT50 SENSOR RANGE MODE Power indicator (green) (Lit when power is supplied.) LIQUID LEAKAGE SENSOR Output indicator (red) (Lit when output is ON.) MODE(OUTPUT) NC NO Resistance adjuster OUT SENSOR RANGE ADJUST K7L-AT50B/AT50DB/AT50DPB Output indicator (red) (Lit when output is ON.) Resistance adjuster Power indicator (green) (Lit when power is supplied.
K7L-AT50@/AT50D@@ Connections External Connections K7L-AT50/AT50B (Bottom view) Signal transmission 4 OUT- 100 mA at 30 VDC max. 6 Level input 1 3 7 Level input 2 2 8 4 3 2 5 2 3 4 F03-20 Terminal Block OUT+ Open-collector output Connecting cable (0.2 mm2 min.) Sensing Band * Use a class 2 power supply for the DC power supply if UL/CSA or CE Marking compliance is required. 1 Note: Always use a 3-conductor cable for wiring and connect to terminals 2, 3, and 4 on the Unit.
K7L-AT50@/AT50D@@ Disconnection detection function (K7L-AT50D/AT50DB/AT50DP/AT50DPB only) Operation While Monitoring for Liquid Leakage • Short-wave signals (2.5 VAC, 3.75 Hz) for liquid leakage detection are output from terminal 4 of the K7L. • When there is no liquid leakage, the liquid leakage detection signals that are output are interrupted by the Terminator and the core of the Sensing Band will form an open loop. Signals interrupted by Terminator.
K7L-AT50@/AT50D@@ Dimensions (Unit: mm) Terminal Block * F03-20 Liquid Leakage Sensor Amplifier K7L-AT50/AT50D/AT50DP 29.1 3 5.8 3 23.1 17.5 5×3=15 2.5 25 3.2 12.8 5.8 17 3.2 46 3.5 Mounting Hole Dimensions 28.8 Two, M3 23±0.2 Liquid Leakage Sensor K7L-AT50B/AT50DB/AT50DPB Terminator F03-20T 24.1 3 18.1 Mounting Hole Dimensions 3 Two, M3 25 3.2 3.2 12.8 18±0.2 46 5.8 12.5 5.8 28.8 17 3.5 3.5 * The Terminal Block is made of nylon 66.
K7L-AT50@/AT50D@@ Track-mounted Sockets * P2RF-08-E Track-mounted Sockets * P2RF-08 (Round terminals can be used.) 7 35.5 71.5 max. 31.5 2 Terminal 4 dia. Arrangement 9.5 (TOP VIEW) 2 73 max. Terminal Arrangement (TOP VIEW) 1.5 48 max. M3 screws 2 3 dia. (21) (22) 3.5 dia. hole 39.5 6 3 5 4 85.5 max. 6 3 7 2 5 4 (11) (12) (24) (14) 35.5 Eight, M3.5 x 8 7 2 8 1 19.5 4 19.5 max. 30 max. 11.5 4 16 54 max. 8 (A1) (A2) 1 61 max. 84 max.
K7L-AT50@/AT50D@@ Mounting Methods Stud Screw Mounting Special Bracket Mounting 1. Securing the Sensor with a Nut 2. Securing the Sensor with a Wing Nut * * Use a commercially available bonding agent for PVC. Safety Precautions Warning Indications WARNING Precautions for Correct Use Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.
K7L-AT50@/AT50D@@ Liquid Leakage Sensor Amplifier K7L Q&A Some questions that are frequently asked about the K7L are given below. Use this information when selecting a model. Q A Can one K7L Amplifier be used for detection in more than one place? Yes. By using Terminal Blocks to connect Sensing Bands in parallel, detection can be performed in more than place with only one K7L Amplifier. Q A K7L-AT50 Possible wiring distance for wiring cable. Can a different terminal block (e.g.
Liquid Leakage Sensor Amplifiers for Long-distance Wiring K7L-U@/-UD@@ Ultra-miniature Liquid Leakage Sensor Amplifier Enables Longest Liquid Leakage Monitoring Distance in Industry • A lineup of new models compatible with Push-In Plus Terminal Sockets is available. • Series of plus common connection compatible products added. • UL listed when used with Push-In Plus Terminal Sockets. *1 *1.
K7L-U@/-UD@@ Model Number Legend K7L-U @ @ (1) (2) (1) (2) Output Symbol Blank D DP Meaning NPN connection PNP connection (Equivalent) Symbol No sensor disconnection detection OK OK Blank Sensor disconnection detection OK NG B Sensor disconnection detection Supports plus common connection NG OK Ordering Information Amplifier Model K7L-U K7L-UB K7L-UD Liquid Leakage Sensor Amplifier with Disconnection Detection Function *1 K7L-UDP K7L-UDB F03-15 Ambient temperature Operating: –10 t
K7L-U@/-UD@@ Nomenclature and DIP Switch Settings K7L-U/UD/UDP Power indicator (green) (Lit when power is supplied.) Output indicator (red) (Lit when output is ON.) Resistance adjuster Sensing Range Settings DIP switch Output Output is OFF when liquid leakage or disconnection is detected. * K7L-UB/UDB/UDPB Output is ON when liquid leakage or disconnection is detected. * Resistance adjuster Output indicator (red) (Lit when output is ON.
K7L-U@/-UD@@ Connections K7L-U/UB (Bottom View) Signal transmission 4 OUT- 100 mA at 30 VDC max. 6 Level input 1 3 7 Level input 2 2 8 Connecting cable (0.2 mm2 min.) 4 3 2 5 2 3 4 F03-20 Terminal Block OUT+ Open-collector output Sensing Band Example: F03-16PE * Use a class 2 power supply for the DC power supply if UL/CSA or CE Marking compliance is required. 1 Note: Always use a 3-conductor cable for wiring and connect to terminals 2, 3, and 4 on the Unit.
K7L-U@/-UD@@ Disconnection Detection Function (K7L-UD/UDB/UDP/UDPB only) Operation While Monitoring for Liquid Leakage Operation While Monitoring for Disconnection • Short-wave signals (2.5 VAC, 3.75 Hz) for liquid leakage detection are output from terminal 4 of the K7L. • When there is no liquid leakage, the liquid leakage detection signals that are output are interrupted by the Terminator and the core of the Sensing Band will form an open loop. 2.5 VAC (3.
K7L-U@/-UD@@ Dimensions (Unit: mm) Terminal Block * F03-20 Liquid Leakage Sensor Amplifier K7L-U/-UD/-UDP 12.8 46 29.1 3 3 2 Liquid Leakage Sensor Amplifier K7L-UB/-UDB/-UDPB 2 25 3.2 2 3 5.8 17.5 2.5 5×3=15 4 28.8 5.8 3 23.1 3 4 17 3.2 4 3.5 Terminator F03-20T 24.1 3 18.1 3 Mounting Hole Dimensions 2-4 (4-2) 12.8 46 Two, M3 25 3.2 3.2 18±0.2 28.8 Track-mounted Sockets P2RF-08 (Round terminals can be used.) 7 Track-mounted Sockets P2RF-08-E 2 73 max. Eight, M3.
K7L-U@/-UD@@ Liquid Leakage Point Sensor F03-16PS F03-16PS-F 8 10 Bottom View 2 Electrode Overall length 2,000 mm Sheath: Fluoroplastic, 0.66 dia. 32 dia. 5.5 dia. Conductor cross section: 0.079 mm2 2.6-dia. vinyl-insulated round cable with 2 conductors Point Sensor Mounting Bracket F03-26PS R5 10 19.2 1 24 1 R3 22.5 6 dia. * Secure the Sockets with M3 screws at a torque of 0.78 to 1.18 N·m. 18 12 8.
K7L-U@/-UD@@ Safety Precautions Warning Indications WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely.
K7L-U@/-UD@@ Liquid Leakage Sensor Amplifier K7L FAQs Some questions that are frequently asked about the K7L are given below. Use this information when selecting a model. Q A Can one K7L Amplifier be used for detection in more than one place? Yes. By using Terminal Blocks to connect Sensing Bands in parallel, detection can be performed in more than place with only one K7L Amplifier. Q A Total: 400 m max. Can a different terminal block (e.g.
F03-16PE/-16PT/-15/-16PS Sensing Band/Point Sensor F03-16PE F03-16PT Liquid Leakage Sensing Band Fluoroplastic Sensing Band • SUS316 used for core and polyethylene used for sheath to ensure high • Compared to the F03-16PE (polyethylene), the F03-16PT has higher resistance to both acidic and alkaline liquids. • Sensing Band Stickers that use the same material as the Sensing Band's insulating resin are available in 2 types: adhesive-tape type and screw type.
F03-16PE/-16PT/-15/-16PS Indicates models that allow free cutting. F03-15 F03-16PS Sensing Band Liquid Leakage Point Sensor • Ideal for harsh electrical room environments that are dusty and humid. • For installation in locations requiring insulated materials. Ordering Information Name Model number Liquid Leakage Sensing Band F03-15 Sensing Band Stickers F03-25 • • • • Can be used in conjunction with Sensing Bands. Stud screw mounting requires no tools for installation.
F03-16PE/-16PT/-15/-16PS Connecting the Sensing Band Connecting F03-20 Terminal Blocks and Sensing Cables Interval Between Stickers The F03-20 Terminal Block is provided to connect the connecting cable from the K7L Liquid Leakage Sensor Amplifier to a Sensing Band in a liquid detection application. When securing the Sensing Band with Stickers, attach the Stickers at intervals of 20 to 30 cm in places where the core is not exposed. Stripping and Connecting Terminals 20 to 30 cm 1.
F03-16SF/-16SFC Liquid Leakage Sensing Band F03-16SF/F03-16SFC Liquid Leakage Sensing Band Greater flexibility and superior workability compared with the F03-16PE. The sheath becomes transparent to reveal the red inner sheath if liquid leakage occurs, thereby enabling visual confirmation. After drying, the Sensing Band color will return to white.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.