Datasheet
K6CM
2
System Configuration
Basic Configuration
*2. For details, refer to the technical data on page 16.
Dedicated tool
EtherNet/IP
Object monitored
K6CM-VBS1
(pre-amplifier)
K6CM-VBM
1 m
(extendable to 100 m)
2.6 m
Single-phase
power supply
Output signal
(transistor output)
Measurement
trigger signal
Built-in EtherNet/IP port
LAN
Note: Even without a computer, the alarm bar of the main unit notifies you of changes of motor state.
By keeping a computer or PLC
continuously connected, you can
monitor the state of a motor.
Sensor head
Connector
Tighten screw
perpendicularly
directly above
rotation shaft
(load side)
0.3 m
Inverter *1
Three-phase
power supply
(pre-wired cable)
(pre-wired cable)
Vibration & temperature monitoring type (K6CM-VB)
*1. Using an inverter helps prevent motor deterioration.
In the conditions below, acceleration fluctuations tend to occur
more frequently.
• The frequency is stable at an inverter drive frequency of 50
Hz or higher.
• The inverter carrier frequency is stable at 12.5 KHz or higher.
Test in the actual installation environment before use.
Dedicated tool
LAN
EtherNet/IP
Built-in EtherNet/IP port
Object monitored
Inverter secondary-side voltage
K6CM-ISM
1 m (extendable to 100 m)
Single-phase
power supply
Output signal
(transistor output)
Inverter
(measurement is also
possible with an inverter)
Three-phase
power supply
40 m max. (From ZCT to motor.
Extendable in some conditions) *2
Note: Even without a computer, the alarm bar of the main unit notifies you of changes of motor state.
By keeping a computer or PLC
continuously connected, you can
monitor the state of a motor.
7.5 kW or less
(Measurement error
increases when this
value is exceeded.)
R
S
T
(pre-wired cable)
(pre-wired cable)
1 m
Insulation resistance monitoring type (K6CM-IS)
Three-phase, three-conductor, S-phase ground