Datasheet

K6CM
10
Motor condition monitoring Tool (Software included with main unit)
Operating Environment
Functions/Specifications (For more details, refer to the catalog of each product.)
* One vibration and temperature type, one insulation resistance type, and one current comprehensive diagnosis type can be set for one motor.
Element Specification
Supported OS Windows 7, Windows 8.1, Windows 10 (32 bit/64 bit) (Japanese/English)
.NET .NET Framework 4 and .NET Framework 3.5
CPU 1 GHz or more, 32 bit or 64 bit processor
Memory 1 GB or more, or 2 GB or more (for 64 bit)
HDD Available space of 16 GB or more, or 20 GB or more (for 64 bit)
Others
Since this software is provided on a CD-ROM, a CD-ROM reading device must be available.
If data is to be collected, a LAN I/F must be available.
Item Specification
Project Number of files that can be created No limit
Import
Supported format CSV data format
Measurement interval that can be imported 1 second to 99999 second (one-second step)
Number that can be
registered in one
project
Number of motors (device groups) 10
Number of devices per motor (device group) 3 *
Graphic display
Type of graph Line graph
Display period
1 hour, 1 day, 1 month, 3 months, 6 months,
1 year, 2 years, 5 years, 10 years, 20 years