Datasheet
K-22 1/32 DIN Digital Panel Meter K3GN
■ Parameters
−
−
−
−
−
−
−
Adjustment level
Press Level Key for less than 1 s.
Power ON
Operation level
Set one
of these.
Set one
of these.
Process value
Note: 1. Some parameters are not displayed for certain models.
2. The K3GN will stop measurement if the level is changed to the initial setting level, the
advanced function setting level, the communications setting level, or the calibration
level.
3. If the input range is changed, some parameters are set to default values. Therefore,
set the input range first.
4. Settings displayed in reverse black/white are defaults.
Commu-
nications
writing
control
OUT1
set value
Upper-limit
OUT1 set
value
Lower-limit
OUT1 set
value
OUT2
set value
Upper-limit
OUT2 set
value
Lower-limit
OUT2 set
value
Monitor Status
Setting Status
Next parameter
The set value
flashes.
If there is no key op-
eration for 5 seconds,
the setting is regis-
tered and the display
returns to monitor sta-
tus.
Change the set
value using the
Up Key and
the Shift Key .
Changing Set Values
While parameters are being displayed, set values can be displayed
by pressing the Shift Key (monitor status).
Pressing the Shift Key again will make it possible for this set value
to be changed (setting status). The part that can be changed will
flash.
Change the set value as required, and press the Mode Key to reg-
ister the setting and move to the next parameter.